Grid-connected hybrid inverter
Hide thumbs Also See for SH4K6:

Advertisement

Quick Links

Quick User Manual
SH3K6 / SH4K6
Grid-Connected Hybrid Inverter
SH3.6_4.6K -QUEN-Ver12-201710
Version:1.2

Advertisement

Table of Contents
loading

Summary of Contents for Sungrow SH4K6

  • Page 1 Quick User Manual SH3K6 / SH4K6 Grid-Connected Hybrid Inverter SH3.6_4.6K -QUEN-Ver12-201710 Version:1.2...
  • Page 3 No part of this document can be reproduced in any form or by any means without the prior written permission of Sungrow Power Supply Co., Ltd. Trademarks and other Sungrow trademarks used in this manual are owned by Sungrow Power Supply Co., Ltd. All other trademarks or registered trademarks mentioned in this document are owned by their respective owners.
  • Page 4: System Overview

    System Overview...
  • Page 9: Table Of Contents

    Contents System Overview ................II  1  Installation ................1      Location Requirements ..................1     Installing the Inverter ................... 2     Grounding the Inverter ..................3     Installing the Meter ....................4 2  Electrical Connection ............... 5   ...
  • Page 10     Viewing the Error Codes .................. 30     LCD Menu ......................31     Setting the Country Code ................32     Setting the Protective Parameters ............... 33     Setting the Communication Parameters ........... 34 6  Troubleshooting ..............35   ...
  • Page 11: Installation

    1 Installation 1.1 Location Requirements  The concrete wall should be suitable for the weight and dimensions of the inverter.  The location should be convenient for installation, cable connection and service.  The location should be not accessible to children. ...
  • Page 12: Installing The Inverter

    1 Installation Quick User Manual  Install vertically for sufficient heat dissipation.  Clearance requirements for single and multiple installation: 1.2 Installing the Inverter Install the inverter on the wall by means of the wall-mounting bracket and the expansion plug sets. The depth of the holes should be about 70 mm.
  • Page 13: Grounding The Inverter

    Quick User Manual 1 Installation 1.3 Grounding the Inverter A second protective earth (PE) terminal is equipped at the side of the inverter. Be sure to connect this PE terminal to the PE bar for reliable grounding. Fig. 1-1 Second PE Terminal In no case shall the second PE connection substitute for the PE connection on the terminal block of AC connector.
  • Page 14: Installing The Meter

    Yellow-green cable wire 1.4 Installing the Meter The SUNGROW meter should be installed next to the main switch. It supports a 35 mm DIN-rail installation, as shown in the following figure. Fig. 1-2 Installing the Energy Meter to the Rail The single-phase Energy Meter and the three-phase Energy Meter are alternative in the delivery.
  • Page 15: Electrical Connection

    2 Electrical Connection For the TT utility grid, the N line voltage to ground must be less than 30 V. 2.1 Terminal Description Fig. 2-1 Configuration Circuit Board Inside the Inverter Label Connection Tool Requirements Copper PV (for parallel mode) Phillips screwdriver Ethernet Communication...
  • Page 16: Meter Connection

    2 Electrical Connection Quick User Manual 2.2 Meter Connection The Sungrow meter should be connected to the distribution board of household loads behind the main switch. For details about the cable connections on the Sungrow meter side, see the Quick Installation Guide for it.
  • Page 17: Pv Connection

    Quick User Manual 2 Electrical Connection 2.4 PV Connection The inverter has two PV inputs and can be configured in independent mode or parallel mode. Refer to the user manual for mode selection. Before connecting the PV arrays to the inverter, ensure that the impedances between the positive terminals of the PV string and Earth, and between the negative terminal of the PV string and Earth are larger than 200 kOhm.
  • Page 18: Communication Connection

    2 Electrical Connection Quick User Manual 2.5 Communication Connection 2.5.1 Ethernet Connection Connect the inverter to the PC through the Ethernet port to set up the Ethernet communication. The Ethernet connection with a router is shown in the following figure.
  • Page 19 Quick User Manual 2 Electrical Connection Use a TIA/EIA 568B standard network cable with a diameter of 3 mm–5.3 mm. Remove the cable jacket by 8 mm–15 mm, and use the Ethernet crimper to crimp the cable. Refer to “4 SolarInfo Moni App Configuration” to use SolarInfo Moin App to view the inverter information.
  • Page 20: Battery Connection

    2 Electrical Connection Quick User Manual 2.5.2 Wi-Fi Connection Unscrew the waterproof lid from the Wi-Fi terminal. Install the Wi-Fi module. Slightly shake it by hand to determine whether it is installed firmly. Refer to the Quick User Manual delivered with the Wi-Fi module to configure the Wi-Fi.
  • Page 21 2.6.2 Connecting the CAN Cable The CAN cable enables communication between the inverter and the Li-ion battery from LG, GCL, Pylon (US2000B), BlueSun, BYD or Sungrow. Take out the CAN cable from the packaging. Lead the cable through the cable gland and tighten the wires to the corresponding terminals.
  • Page 22: Do Connection

    2 Electrical Connection Quick User Manual 2.6.4 Connecting the Temperature Sensor It is recommended that the PT1000 is connected to the inverter to sample the temperature of the lead-acid battery or the external environment of the battery. The temperature sensor is located next to the lead-acid battery. Cross-section: 1.0 mm², cable diameter: 3 mm–5.3 mm 2.7 DO Connection The inverter has two DO relays with different functions as follows:...
  • Page 23: Retrofitting The Existing Pv System

    The hybrid inverter is compatible with any single-phase PV grid-connected inverters. An existing PV system can be retrofitted to be a PV Energy Storage System with the addition of SH3K6 / SH4K6. The power generation from the existing PV inverter will be firstly provided to the loads and then charge the battery.
  • Page 24 70 % of the installation capacity. For example, with a total maximum installation capacity of 4600 W (SH4K6), the export power should be set to 3220 W (i.e. 4600 * 70 %). The settings in the two submenus are from the same source. If one is...
  • Page 25: Connecting To Interface Device For Spi (Italy)

    Quick User Manual 2 Electrical Connection 2.9 Connecting to Interface Device for SPI (Italy) The inverter has integrated the interface protection system (SPI) to provide the following functions:  Maximum/minimum frequency protection;  Ability to receive signals aimed at changing the frequency protection thresholds and to receive the command of remote shutdown.
  • Page 26: Commissioning

    3 Commissioning 3.1 Button Function The inverter offers four buttons for operation. Please refer to the following table before any operation of the inverter. Tab. 3-1 Button Function Button Description For navigating up or increasing the setting value. For navigating down or decreasing the setting value. For navigating to the left, quitting the menu or canceling the settings.
  • Page 27: Commissioning Procedure

    Quick User Manual 3 Commissioning 3.2 Commissioning Procedure Before starting the inverter, make sure all the installation and connections are completed and verified. Proceed as follows to start the inverter for the first time. Connect the AC circuit breaker. Connect the DC circuit breaker between the inverter and the battery pack. (Optional) Power on the battery pack manually if a battery is equipped.
  • Page 28 3 Commissioning Quick User Manual Fig. 3-2 Initial Settings...
  • Page 29 70 % of the installation capacity. For example, with a total maximum installation capacity of 4600 W (SH4K6), the export power should be set to 3220 W (i.e. 4600 * 70 %).  Reactive power regulation: OFF: The reactive power regulation function is disabled.
  • Page 30 3 Commissioning Quick User Manual “Li-ion Pylon” option: “Li-ion GCL” option: “Li-ion BlueSun” option: “Li-ion BYD” option: “Other Lead-acid” option: Max. Chrg / Max. DChrg: Make sure that the charge or discharge current is not beyond the upper limit (65 A) to protect the battery from overcharging or deep discharging.
  • Page 31: Result Verification

    Quick User Manual 3 Commissioning Tab. 3-3 Description of Other Lead-acid Battery Parameter Parameter Description Default Range upper limit Max. Chrg 0.300C 0.05C to 2C charging current upper limit Max. DChrg 0.300C 0.1C to 2C discharging current The rated voltage of the Rate Vtg 48.0 V 30 V to 60 V...
  • Page 32 3 Commissioning Quick User Manual Fig. 3-3 Correct Installation and Connection of the Single-phase Meter * The CT clamp of 1-phase sensor can be placed before or after the main switch. The following figure shows the correct installation and connection of the three-phase meter.
  • Page 33 3 Commissioning For Incorrect Installation Position Make sure that the 1-phase sensor of the SUNGROW meter should be placed to the phase line (L) from the main switch. If otherwise, the energy flow indicated on the LCD will be wrong.
  • Page 34: Battery Information

    3 Commissioning Quick User Manual Fig. 3-6 Correct Power cable connection for Three-phase Meter Action LCD Display Explanation Method 1: Turn off all the household loads. All the PV power generation should be exported to the grid, as shown in the “Correct” figure. Method 2: Stop the inverter via the LCD menu and turn on the household...
  • Page 35 Quick User Manual 3 Commissioning If the battery type or capacity setting is inconsistent with the actual, the charge/discharge current may be less than the actual charge/discharge ability. However, the system can operate normally. Proceed as follows to modify. Stop the inverter via the LCD menu. Main Screen (Press ENT)→Menu (Press ×1)→ON / OFF (Press ENT) Confirm your choice by pressing ENT.
  • Page 36: Solarinfo Moni App Configuration

    4 SolarInfo Moni App Configuration If the inverter has been connected to the home router with an Ethernet cable, the user can view inverter information via the SolarInfo Moni App. 4.1 App Operation Requirements Item Android System iOS System System version Android 4.0 or above iOS 7.1 or above 1280*720,...
  • Page 37: Visiting In "Local Access" Mode

    Quick User Manual 4 SolarInfo Moni App Configuration Search for SolarInfo Moni in your App Store to download and install it. For Android Download SolarInfo Moni http://www.solarinfobank.com/app/list. Choose the SolarInfo Moni App for Android. Use the scanning function of the Play Store or Explorer in your smart phone to scan the QR code to download and install the App.
  • Page 38: Visiting In "[Login]" Mode

    4 SolarInfo Moni App Configuration Quick User Manual Visit the App in “Local Access” mode, select you inverter SN and input the password, then you can view the inverter information. 4.4 Visiting in "[Login]" Mode Connect the inverter to your home router and complete the App registration. Then you can visit SolarInfo Moni App in "[Login]"...
  • Page 39: Operation

    Running: The inverter is in its normal running state. 16:37: Current system time. Neither the grid power nor the load power will be displayed on the main screen in case of no SUNGROW meter installed. Tab. 5-1 State Descriptions State Description After being energized, the inverter tracks the PV arrays’...
  • Page 40: Viewing The Error Codes

     Whether the battery level is sufficient and the cable connection is correct.  If no anomaly is found, disconnect the DC switch and main switch to restart.  If it still does not work, contact SUNGROW. 5.2 Viewing the Error Codes Viewing the Active Error For the icon or the “Error”...
  • Page 41: Lcd Menu

    Quick User Manual 5 Operation Viewing the Error Records ×5)→Error Record (Press ENT) Main Screen (Press ENT)→Menu (Press Press to turn pages and view all error records. 5.3 LCD Menu Fig. 5-1 LCD Menu Tree (1) The power values indicated represent the average values during the time interval.
  • Page 42: Setting The Country Code

    5 Operation Quick User Manual (2) The value of battery SOH will be displayed as “--” for Pylon US2000A and GCL battery that do not have this parameter. (3) The “Restart” option will appear only if an unrecoverable fault occurs. Abbreviations Abbreviation Complete...
  • Page 43: Setting The Protective Parameters

    Quick User Manual 5 Operation Descriptions of the country codes are as follows: Country Code Full Name Language Great Britain English Germany German Italy Italian Austria German Australia English Belgium French Netherlands English China Chinese South Africa English Other Country not included above English 5.5 Setting the Protective Parameters ×2)→Settings (Press ENT)→Input...
  • Page 44: Setting The Communication Parameters

    5 Operation Quick User Manual Tab. 5-2 Protective Parameter Explanations Parameter Explanation Recovery value for over-voltage fault. Inverter can start Vmax-recover operating only when the grid voltage is below this value. Recovery value for under-voltage fault. Inverter can start Vmin-recover operating only when the grid voltage is above this value.
  • Page 45: Troubleshooting

    2. Rotate the DC Switch to “OFF”. screen cannot be lit. 3. Check the polarities of the DC inputs. 4. If all of the above are OK, please contact SUNGROW. 1. Disconnect the AC circuit breaker. 2. Rotate the DC Switch to “OFF”.
  • Page 46 6 Troubleshooting Quick User Manual For Inverter Side Code Specification Troubleshooting 1. Check the grid voltage. Grid over-voltage. 2. If the grid voltage exceeds the (default range: 264.5 V) permissible range, consult the utility grid for a solution. Temporary grid over-voltage in This is a short-term fault.
  • Page 47 45℃. If not, please contact SUNGROW for a solution. Wait 5 minutes for inverter recovery Relay fault on the grid side. or restart the system. 041, Wait 5 minutes for inverter recovery Leakage current sampling fault.
  • Page 48 1. Check if the fan is blocked. Fan2 abnormal speed warning. 2. Restart the system. 1. Check whether the power cable connections are correct. 2. For Sungrow single-phase meter, Warning reverse cable check whether the CT clamp of the connection Sungrow 1-phase sensor is correctly placed.
  • Page 49 PV1 boost short-circuit fault The inverter may be damaged. PV2 boost short-circuit fault Contact SUNGROW for a solution. 1. Check and clean the heat sink. 2. Check whether the inverter is installed in sunlight or the ambient INV over-temperature fault.
  • Page 50 Abnormal communication Check whether RS485 warning of the Sungrow Meter. connection is correct. (Inverter normally 3. Check if the 120 Ohm (2) resistor connected to the grid.) for RS485_2 is pushed to “ON” when the length of RS485 cable is longer than 100 m.
  • Page 51 Quick User Manual 6 Troubleshooting Code Specification Troubleshooting installed in sunlight or the ambient temperature enclosure exceeds 45℃. 3. Restart the system. 1. The inverter can normally be connected grid Transformer direction charge/discharge has stopped. recognition error. 2. Wait a moment for system recovery or restart the system.
  • Page 52 4. Wait a moment for system recovery or restart the system. Restart the system, if the fault persists, ID competing failure. please contact SUNGROW for a solution. inverter normally connected grid 837, charge/discharge has stopped.
  • Page 53 Quick User Manual 6 Troubleshooting Code Specification Troubleshooting imbalance fault. battery communication cable connection. 3. Force a shutdown and restart the Battery cable connection inverter and battery system. fault. 4. Wait a moment for system recovery or restart the system. inverter normally connected...
  • Page 54: Appendices

    7 Appendices 7.1 Inverter Technical Data PV Input Data SH3K6 SH4K6 Max. PV input power 6500 W 6500 W Max. PV input voltage 600 V 600 V Startup voltage 125 V 125 V Nominal input voltage 360 V 360 V MPP voltage range 125 V–560 V...
  • Page 55 Quick User Manual 7 Appendices > 0.99 at default value at nominal power Power factor (adj. overexcited/leading–0.8 underexcited/lagging) Protection Anti-islanding protection AC short circuit protection Leakage current protection DC switch (solar) DC fuse (solar) DC fuse (battery) Over-voltage category III [Main], II [PV] [Battery] System Data Max.
  • Page 56: Meter Technical Data

    7 Appendices Quick User Manual 7.2 Meter Technical Data Item Single-phase Three-phase Nominal voltage 240 Vac 230 Vac / 400 Vac Input voltage range 180 Vac–286 Vac 180 Vac–276 Vac Power consumption < 2 W (10 VA) < 2 W (10 VA) Max.
  • Page 57 The power rating of SUNGROW products covers from hundred watt to mega-watt systems. The vision of SUNGROW is to help our customers acquire stable and clean power with minimum cost, maximum reliability and enhanced safety. Contact Information Should you have any problems, please contact us through the following information.