10.4 Tape replacement
THE REPLACEMENT OF THE TAPE DOES NOT REQUIRE
TO RE-CALIBRATE THE TEMPERATURE.
Follow the different sequences as described below. The
Figure 13-1: general assembly, list of the main spare parts
can also help.
10.4.1 Disconnecting the tape from the sensor
Follow the instructions of section 10.5 "Sensing probe
replacement".
10.4.2 Disconnecting the tape from the electronic box
• Unscrew with the 2.5 Allen key the 2 screws (A) of the battery
holder and pull it out as shown on Figure 10-5.
• Unscrew with the 2.5 Allen key the 4 screws (B) of the display
unit and pull it gently out as shown on Figure 10-5.
(B)
40
www.tanksystem.com
Figure 10-5
• Disconnect the connecting plug (C) as shown on Figure 10-6
and remove the display unit.
• Unscrew with the 2.5 Allen key the tape holder (G) by
removing the 2 screws (F) and the grounding cable (D) as
shown on Figure 10-6. Do not loose the 2 remaining screws
that secure the reel axle.
(C) connecting plug
to display unit
(A)
(D) grounding cable of tape
(E) black oversleeve of tape
(F) securing screw
(G) tape holder
(H) tape
(I) securing screw
Figure 10-6