Fitting Instructions - Stanley Cara Plus Installation And Operating Instructions Manual

Solid fuel high output boiler insert stove
Table of Contents

Advertisement

Fig.4

FITTING INSTRUCTIONS

Step 1
Prepare the fireplace area. Ensure the opening is
suitable for fitting of the insert stove opening
required, i.e. remove fire surround trim if fitted. See
Fig.5.
Fig.5
405mm - 455mm
Step 2
Ensure the floor area is level with the hearth, this
area needs to be level as the insert fire is screw
fixed to the floor.
Step 3
Decide which boiler tappings are to be used to con-
nect the boiler. Remove the temporary plugs from
the other two connections and replace with perma-
nent boiler plugs.
5" - 8"
Adaptor/
Closure Plate
240mm - 320mm
Min 380mm
Step 4
Remove all internal parts as per pre-assembly
instructions prior to lifting it.
Step 5
Inset the stove to its final position.
USING CLOSURE PLATE - (Skip to Step 10)
Step 6
Drop the 150mm twin wall flexi flue liner down
through the chimney and into the stove.
Step 7
Lay the sealing gasket on to the flue spigot, connect
the flue spigot to the flexi pipe using a 5" extension
pipe and a 5" - 6" adaptor. It is not recommended to
fit a flexi flue liner within 600mm of the stove flue
spigot.
Step 8
Pull the flexi liner back up through the flue outlet and
fix the flue spigot into position using the M8 bolts
provided. It may be necessary to cut a prop to hold
the spigot in place while the fixings are being
attached.
Step 9
Complete the installation of the flexi liner at the top
of the chimney in accordance with the manufactur-
ers instructions.
USING FLEXIBLE LINER - (Skip to Step 16)
Chimney Connectors
Fig.6
Offset Adaptor
Step 10
Measure the distance to the flue outlet of the stove
and compare to the chimney, decide on best orien-
tation of the offset adaptor.
Step 11
Push the offset adaptor into position and make a
seal using approved fire cement between the adap-
tor and the clay liner. The seal should be tapered to
allow any condensation that may occur in the
chimney flow back into the flue. See Fig.7.
8
Extension Pipe
15 degree Adaptor

Hide quick links: