Any existing chimney must be clear of obstruction
and have been swept clean immediately before
installation of the stove. If the stove is fitted in place
of an open fire then the chimney should be swept
one month after installation to clear any soot falls
which may have occurred due to the difference in
combustion between the stove and the open fire.
If there is no existing chimney then any new system
must be to the designation described above and in
accordance with Building Regulations Approved
Document J.
A single wall metal fluepipe is suitable for connecting
the stove to the chimney but is not suitable for use
as the complete chimney. The chimney and con-
necting flue must have a minimum diameter of
150mm and at no point must the diameter reduce to
less than the size of the outlet socket of the stove.
Any bend in the chimney or connecting fluepipe
should not exceed 45
used.
Combustible material should not be located where
the heat dissipating through the walls of fireplaces or
flues could ignite it. Therefore when installing the
stove in the presence of combustible materials due
account must be taken of the guidance on the sepa-
ration of combustible material given in Building
Regulations Approved Document J and also in these
stove instructions.
If it is found that there is excessive draught in the
chimney then a draught stabiliser should be fitted.
Fitting of a draught stabiliser will affect the require-
ment for the permanent air supply into the room in
which the stove is fitted in accordance with
Approved Document J (see also combustion air sup-
ply).
Adequate provision e.g. easily accessible soot door
or doors must be provided for sweeping the chimney
and connecting fluepipe.
ALL FLUE INSTALLATIONS ARE THE
RESPONSIBILITY OF THE CUSTOMER.
o
o
. 90
bends should not be
Fig.3
Fig.4

FITTING INSTRUCTIONS

Fully Lined Chimney

Step 1
Prepare the fireplace area. Ensure the opening is
suitable for fitting of the insert stove opening
required, i.e. remove fire surround trim if fitted. See
Fig.5.