Do not overtighten the roof bolts when refitting the
baffle. It is adequate to leave them in a position
where the L shaped bracket has just enough room to
be removed.
To remove the cast iron liners, lift them clear of the
grate support plate and then move the front edge of
the casting towards the middle of the stove, and
clear of the back wall of the stove, then tilt the cast-
ing so that it can be removed diagonally through the
opening. Remove the flue spigot and gasket by
removing the four bolts.
Next, remove the grate by pushing it from under-
neath, the riddling bar is not fixed to the grate. This
will allow access to two M6 fixings which will attach
the stove to the outer casing. Remove the 2 fixings,
allowing the insert stove to be removed from the
external casing.

CHIMNEY

THIS PRODUCT IS SUITABLE FOR CHIMNEY
INSTALLATION ONLY.
The stove is a radiant room heater and must be con-
nected to a chimney of the proper size and type. For
ROI the chimney must have a diameter of at least
125mm. It is recommended that a flue liner of diam-
eter 125mm be used to line the chimney, the liner
should be approved for use with solid fuel. See
Fig.3.
For the UK the chimney must have a diameter of at
least 150mm, an adaptor is available where required
to fit between the flue outlet and a 6" flexible flue
liner.
Never connect to a smaller size chimney. Do not
connect to a chimney serving another appliance.
Minimum chimney height 4.5 meters from floor on
which stove is installed.
It is permitted to connect using a closure plate and a
connection piece from the stove to the closure plate
(See Fig. 4), provided that the chimney is of sound
Fig.2B
construction with no leaks or cracks, a clay flue liner
has been used that can withstand up to 1000
clay liner has a diameter no greater than 200mm.
The chimney must be swept and examined for
soundness and suitability before the appliance is
installed. Remedial action should be taken if
required, seeking expert advice if necessary.
Chimneys must conform to BS EN 15287-1:2007:
Design, installation and commissioning of chimneys.
ALL FLUE INSTALLATIONS ARE THE
RESPONSIBILITY OF THE CUSTOMER.
The stove must be connected to a chimney with a
minimum continuous draught of 12 Pascal's. Poor
draught conditions will result in poor performance.
Fig.3
Note:-
If the stove is fitted in place of an open fire, then the
chimney should be swept one month after
installation to clear any soot falls which may have
occurred due to the difference in combustion
between the stove and the open fire.

FITTING INSTRUCTIONS

Fully Lined Chimney

Step 1
Prepare the fireplace area with millner brick removal.
Ensure the opening is suitable for fitting of the insert
stove opening required, i.e. remove fire surround
trim if fitted. See Fig.4.
3