Tektronix SPG600 Service Manual page 85

Sync pulse generators
Hide thumbs Also See for SPG600:
Table of Contents

Advertisement

SPG600 & SPG300 Sync Pulse Generators Service Manual
3. Recall the Factory Default preset as follows:
a. Press the SYSTEM button to display the System menu.
b. Press the ENTER button to display the Preset submenu.
c. Press the left ( ) or right ( ) arrow button to select Factory Default.
d. Press the ENTER button to recall the factory default settings.
4. Select the 75% Color Bars signal as follows:
a. Press the VIDEO button to display the Video menu.
b. Press the up ( ) or down ( ) arrow button to select TEST SIGNAL
(SDI).
c. Press the ENTER button.
d. Press the left ( ) or right ( ) arrow button to select 75% Color Bars.
5. Turn on the logo overlay as follows:
a. Press the CANCEL button to return the Video menu.
b. Press the up ( ) or down ( ) arrow button to select OVERLAY.
c. Press the left ( ) or right ( ) arrow button to select SDI (STD).
d. Press the ENTER button to display the Overlay submenu.
e. Press the left ( ) or right ( ) arrow button to select Logo.
f.
Press the ENTER button to display the Logo submenu.
g. Press the left ( ) or right ( ) arrow button to select a logo.
6. Turn on the embedded audio for Group 1 as follows:
a. Press the AUDIO button to display the Audio menu.
b. Press the up ( ) or down ( ) arrow button to select EMBEDDED
(STD/TEST).
c. Press the left ( ) or right ( ) arrow button to select Group 1.
d. Press the ENTER button to display the Embedded submenu.
e. Press the left ( ) or right ( ) arrow button to select Enable.
f.
Press the ENTER button.
7. Press the Measure button on the video measurement set to open the Measure
mode display.
Performance Verification
4-13