Tektronix SPG600 Service Manual page 75

Sync pulse generators
Hide thumbs Also See for SPG600:
Table of Contents

Advertisement

Table 4-2: SPG600 and SPG300 calibration data report (cont.)
Serial Number:
Step
9.
Sync Amplitude
10.
Serial Output Amplitude
11.
Serial Output Rise Time (20% to 80% amplitude points)
12.
Serial Output Fall Time (20% to 80% amplitude points)
13.
Serial Output Amplitude
14.
Serial Output Rise Time (20% to 80% amplitude points)
15.
Serial Output Fall Time (20% to 80% amplitude points)
SPG600 & SPG300 Sync Pulse Generators Service Manual
Cal Data:
Function Tested
Temperature:
Minimum
CH 5
277.1 mV
CH 6
277.1 mV
CH 7
277.1 mV
CH 8
277.1 mV
SDI 1
720 mV
SDI 2
720 mV
SDI 1
0.4 ns
SDI 2
0.4 ns
SDI 1
0.4 ns
SDI 2
0.4 ns
SPG600 Option 03
SDI 5
720 mV
SDI 6
720 mV
SDI 5
0.4 ns
SDI 6
0.4 ns
SDI 5
0.4 ns
SDI 6
0.4 ns
Performance Verification
Humidity:
Cal Data
Maximum
mV
mV
mV
mV
mV
mV
ns
ns
ns
ns
mV
mV
ns
ns
ns
ns
294.3 mV
294.3 mV
294.3 mV
294.3 mV
880 mV
880 mV
1.50 ns
1.50 ns
1.50 ns
1.50 ns
880 mV
880 mV
1.50 ns
1.50 ns
1.50 ns
1.50 ns
4-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spg300

Table of Contents