Roland SK-50 Owner's Manual page 45

Sound canvas multi timbral keyboard
Hide thumbs Also See for SK-50:
Table of Contents

Advertisement

Byte
Description
=========================================================
F0H
Exclusive status
41H
ID number
(Roland)
dev
Device ID
(dev: 00H-1FH(1-32) The default value is 10H(17).)
42H
Model ID
(GS)
12H
Command ID (DT1)
40H
Address MSB
00H
:
7FH
Address LSB
00H
Data
(GS reset)
sum
Checksum
(The checksum when dev.=10H(17) is 41H.)
F7H
EOX
(End of exclusive)
* Upon receiving this message, all the internal parameters are set to the default
settings of the GS Format. ( Rx.NRPN SW will be turned ON by this message.)
* It takes about 50ms to execute this message.
* Refer to Section.4 to calculate the checksum.
- Turn General MIDI System On
Status Data Byte
F0H
7EH, 7FH, 09H, 01H
Byte
Description
=========================================================
F0H
Exclusive status
7EH
ID number
7FH
ID of target device
09H
sub-ID#1
01H
sub-ID#2
F7H
EOX
* Upon receiving this message, all the internal parameters are set to the default
settings of General MIDI System Level 1. ( Rx.NRPN SW will be turned OFF by
this message.)
* It takes about 50ms to execute this message.
•Universal Realtime System Exclusive Message
- Master Volume
Status
Data Byte
F0H
7FH, 7FH, 04H, 01H, llH, mmH
Byte
Description
=========================================================
F0H
Exclusive status
7FH
ID number
7FH
ID of target device
04H
sub-ID#1
02H
sub-ID#2
mm,ll
Master Volume
F7H
EOX
* The LSB (llH) is ignored(value=0).
* Devices whose "Rx.Sys.Ex.SW = OFF" won't recognize this message.
•Data Transfer
SK-50 can transmit and receive the various parameters using System Exclusive
messages of the following data format.
GS Common Exclusive messages use Model ID = 42H and Device ID = 17(10H).
- Request data 1 RQ1
This message is sent out to request the remote device to send back the required
data.
It contains data for the address and size that specify designation and length,
respectively.
44
Status
F7H
(Universal non-real time message)
(Broadcast)
(General MIDI message)
(General MIDI On)
(End of exclusive)
Status
F7H
(Universal Realtime message)
(Broadcast)
(Device Control Message)
(Master Volume)
00 00H - 7F 7FH ( 0 - 16383 )
(End of exclusive)
On receiving a proper RQ1 message for the device, the device will transmit a
"Data set 1 (DT1)" message, which contains the requested data. Otherwise, the
device will not send anything.
Status
Data Byte
F0H
41H, dev, 42H, 11H, aaH, bbH, ccH, ssH, ttH, uuH, sum F7H
Byte
Description
=========================================================
F0H
Exclusive status
41H
Manufacturer's ID (Roland)
dev
Device ID
(dev: 00H-1FH(1-32) The default value is 10H(17).)
42H
Model ID
(GS)
11H
Command ID (RQ1)
aaH
Address MSB
bbH
:
ccH
Address LSB
ssH
Size MSB
ttH
:
uuH
Size LSB
sum
Checksum
F7H
EOX
(End of exclusive)
* SK-50 only recognize the RQ1 messages whose address and size match the
Parameter Address Map (Section 3).
* The error checking process uses a Checksum. Refer to Section 4 to calculate a
Checksum.
- Data set 1
DT1
This message corresponds to the actual data transfer process.
On receiving a DT1 message, the device writes the data to internal memory
according to the address.
Status
Data Byte
F0H
41H, dev, 42H, 12H, aaH, bbH, ccH, ddH, ... eeH, sum
Byte
Description
=========================================================
F0H
Exclusive status
41H
Manufacturer's ID (Roland)
dev
Device ID
(dev: 00H-1FH(1-32) The default value is 10H(17).)
42H
Model ID
(GS)
12H
Command ID (DT1)
aaH
Address MSB
bbH
:
ccH
Address LSB
ddH
Data
:
:
eeH
Data
sum
Checksum
F7H
EOX
(End of exclusive)
* SK-50 only recognize the DT1 messages whose address and size match the
Parameter Address Map (Section 3).
* To send large DT1 messages at a time, insert 40ms - intervals at least in
between each packet.
* The error checking process uses a Checksum. Refer to Section 4 to calculate a
Checksum.
2.Transmit data
Channel Voice Messages
These messages will always be sent on the channel having the same number as
the reception channel of the currently selected part.
Status
Status
F7H