Page 1
INSTALLATION AND OPERATION INSTRUCTIONS FOR 50-TRU-VIEW-XL 60-TRU-VIEW-XL 72-TRU-VIEW-XL SAFETY INFORM ATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or ot her flammable vapors and liquids in t he vicinit y of t his or any ot her appliance.
Amant ii product . IMPORTANT INSTRUCTIONS............................3 UNPACKING AND TESTING APPLIANCE .......................3 GROUNDING APPLIANCE ............................3 LOCATING THE FIREPLACE .............................4 50-TRU-VIEW-XL.................................5 60-TRU-VIEW-XL.................................6 72 –TRU-VIEW-XL ...............................7 INSTALLATION................................8 SAFETY DRILL SCREW AREA ..........................1 4 FOR BATHROOM USE ...............................
IM PORTANT INSTRUCTIONS Read all inst ruct ions before inst alling or using t his heat er. Keep combust ible mat erials, such as furnit ure, pillows, bedding, papers, clot hes and curt ains at least 3 feet from t he front of t he heat er; keep t hem away from sides and rear as well. ’...
UNPACKING AND TESTING APPLIANCE Carefully remove t he appliance from t he box. Prior to inst alling t he appliance, t est t o make sure t he appliance operat es properly by plugging t he power supply cord int o a convenient ly located 120 Volt grounded out let .
50-TRU-VIEW-XL This appliance has been tested in accordance wit h t he UL St andard 2021 Descript ion Built-in Appliance fixed locat ion dedicated Voltage 120V AC 60Hz elect ric room appliances in t he Unit ed Watt s 1500W M ax St ates and Canada.
60-TRU-VIEW-XL This appliance has been tested in accordance wit h t he UL St andard 2021 M odel Number Build-in Appliance fixed locat ion dedicated Voltage 120V AC 60Hz elect ric room appliances in t he Unit ed Watt s 1500W M ax St ates and Canada.
TRU-VIEW-XL – This appliance has been tested in Descript ion Built-in Appliance accordance wit h t he UL St andard 2021 fixed locat ion dedicated Voltage 120V AC 60Hz elect ric room appliances in t he Unit ed Watt s 1500W M ax St ates and Canada.
The rough wall opening size of t he fireplace: " " " 2. Take off t he fending bars and panels if you 50-TRU-VIEW-XL 53 3/4 14 3/ 4" 27 1/8 want to view t he fire from t hree angles. 60-TRU-VIEW-XL 63 3/4 14 3/ 4"...
Page 9
framing plat e framing plat e 5. M ake an opening for t he fireplace according t o requested measurement . 7. After checking t hat t he fireplace operat es properly, cover t he glass panels wit h protect ive plast ic bag and inst all polywood.
Page 10
8. Decorat e t he polywood wit h glazed t ile, fending bar and panel. wallpaper, et c. 3. Aft er t he fending panel is removed, screw back t he bar. Installation for Front and Right Side V iew ing 1.
Page 11
5. M ake an opening for t he fireplace according 7. After checking t hat t he fireplace operat es t o requested measurement . properly, cover t he glass panels wit h protect ive plast ic bag and inst all polywood. 6.
Page 12
Installation for Front and Left Side V iew ing 1. Inst all t he fireplace where t he right side is close t o a wall, and you want t o view t he fire from front and left side, t ake off t he fending panel on t he left .
Page 13
7. After checking t hat t he fireplace operat es properly, cover t he glass panels wit h protect ive plast ic bag and inst all polywood. 6. Insert t he fireplace int o t he wall opening. Drive t he mount ing screws int o t he frame plat es To fix the bottom on t he unit and t he wall st uds.
SAFETY DRILL SCREW AREA There is a safet y drill screw area as show below. Please make sure t hat t he fix screws are in t his area. T h e m a n u a l c o n tro l p a d p o s itio n Sa fe ty d rill s cre w a re a (Da rk a re a ) For Bathroom Use...
HARD- W IRE INSTALLATION Turn off t he appliance complet ely and let cool before servicing. Only a qualified service person should service and repair t his elect ric appliance. If it is necessary t o hard wire t his appliance, a qualified elect rician must remove t he cord connect ion, and wire t he appliance direct ly t o t he house hold wiring.
OUTDOOR INSTALLATIONS TRU-VIEW-XL, BI-DEEP & BI-SLIM electric fireplaces are suitable for installa on in outdoor areas protected from direct water impingement. In addi on to maintaining the listed mantel and combus bles clearances, a rain protec on overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance.
M edia Options The 50-TRU-VIEW-XL and 60-TRU-VIEW-XL are shipped w it h 2 set s of FI-109-DIAM OND, 72-TRU-VIEW- -XL is shipped w it h 3 set s of FI-109-DIAM OND. FI-109-DIAM OND 3 glass nugget s, 1 bag of clear, 1 bag of small clear, 1 bag of clear diamond and 1 bag of blue diamond.
M edia Operation 1. Unscrew 2 screws and take off two brackets which are fending the front glass panel. S crews and brackets 4. Inst alling t he fire glass media. Pour t he fire glass media int o t he t ray as shown below. Feel free to use any combinat ion of fire glass 2.
OPERATION The fireplace can be operat ed eit her by t he swit ches located on t he left bot t om of t he fireplace unit or by supplied remot e cont rol. Plug t he fireplace int o a 15 Amp wall socket . M ANUAL OPERATION The main power ON/ OFF swit ch in posit ion O, t he fireplace is OFF.
REM OTE CONTROL OPERATION For remot e t o funct ion make sure t he heater is plugged in and main power swit ch locat ed on t he bott om left hand side is at posit ion I. When operat ing t he remot e make sure you point t he remote t o t he cent re of t he fireplace and make sure each t ime you press t he butt on.
INSTALLING WALL THERM OSTAT WALL THERM OSTAT W IRING DIAGRAM S W ire the wall thermostat prior to installing the fireplace. WALL THERM OSTAT W IRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the follow ing information: Turn off circuit breaker.
REPLACEMENT PARTS This list contains replacement parts PART NUMBER DESCRIPTION 50-TRU-VIEW-XL 60-TRU-VIEW-XL 72-TRU-VIEW-XL 10701216 10701217 10701218 FRONT CLEAR GLASS 10201505 ADJUSTABLE SCREW 3123010 FRONT CLEAR GLASS BRACKET 10702168 10702169 10702170 BOTTOM TRAY GLASS 10701219 10701220 10701221 BACK GLASS WITH BLACK...
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION ’ ’ Dim or no flame Flame LED s are burnt out Inspect t he LED s and replace t hem if necessary. ’ ’ Ember Ember LED s are burnt out Inspect t he ember bed LED s and glowing or dimming replace t hem if necessary.
SERVICE HISTORY This heat er must be serviced annually depending on usage. Date Dealer Service technician Service Performed Special Concerns Name Name NOTES:...