Indicator
Alarm/Maintenance
indicator
Rear View
Figure 2-7
Issue 04 (2016-06-20)
Status
Off
Alarm state
Local
maintenance
state
Local maintenance refers to operations performed after a universal serial bus (USB) flash drive,
Bluetooth module, or USB data cable is inserted into the USB port of the SUN2000. For example,
local maintenance includes data import and export using a USB flash drive and connecting to the
SUN2000 APP over a Bluetooth module or USB data cable.
If alarming and local maintenance happen concurrently, the alarm/maintenance indicator shows the
local maintenance state first. After the USB flash drive, Bluetooth module, or USB data cable is
removed, the indicator shows the alarm state.
shows the SUN2000 rear view.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Meaning
The inverter has not received
data over RS485/PLC
communication for 10 seconds.
Blinking red
The SUN2000 has generated a
slowly (on for
warning.
1s and then off
for 4s)
Blinking red
The SUN2000 has generated a
fast (on for
minor alarm.
0.5s and then
off for 0.5s)
Steady red
The SUN2000 has generated a
critical alarm.
Blinking green
Local maintenance is in
slowly (on for
progress.
1s and then off
for 1s)
Blinking green
Local maintenance has failed.
fast (on for
0.125s and off
for 0.125s)
Steady green
Local maintenance is successful.