writing bL0c with flashing dashes: enter the password to unlock the keyboard, which
will be unlocked for 30 seconds from the last pressure.
System operation hours
This page shows the total number of hours of the
system operation (relay ON) for the current mode
(indicated by the icons
The hour meter has 4 digits and is resettable by
pressing for a long time the key
appears.
During manual operation the device performs as a normal thermostat, adjusting on the
basis of the Tm temperature (manual setpoint), independently from the day and the
time where it is.
The manual operation is signalled with the switch on of the symbol
To move from automatic operation to manual operation:
1. press briefly the key
2. set the desired setpoint with the keys
3. at this point on field (7) the value of the environment temperature reappears and
the instrument operates in manual.
If you want to change the setpoint (Tm) press the key
and 3.
To go back to the automatic operation press for a long time the key
about).
or
).
until 0000

MANUAL OPERATION

. In the field (7) the setpoint (Tm) currently set flashes
and
- 32 -
Dafne chronothermostat, user's manual
in the field (5).
and confirm with the key
and repeat the points 2
(3 seconds