During automatic operation, when pressing the " " key, the system will act as a
normal thermostat with operating temperature Tm.
Field
will show the current time.
Field
will show the current date.
Field
will display the writing "SEt".
The symbol
will appear.
Field
will disappear. On field
set manual temperature value will flash.
With the "
" and "
possible to change the value from 2.0°C
to 35°C.
Pressing the " " key or after 45 seconds
from the last operation, field
display the value of the environment
temperature, while field
the external temperature value (if probe is
connected).
At any time, it is possible to verify the
set temperature pressing the "
or the "
" key; pressing one of the 2
keys again will allow modification of the
temperature setting. To move from the
manual program to the automatic one,
simply press the " " key again for at
least 3 seconds.
MANUAL OPERATION
the
" keys, it is
will
will display
" key
- 44 -