9.4.28 Sets the reading timeout
•
Command syntax:
•
Command answer:
•
Command action:
•
Parameter range:
Description: this command sets the reading timeout in seconds.
9.4.29 Gets the reading timeout
•
Command syntax:
•
Command answer:
•
Command action:
•
Parameter range:
Description: this command retrieves the reading timeout in seconds.
9.4.30 Sets the shutdown timeout
•
Command syntax:
•
Command answer:
•
Command action:
•
Parameter range:
Description: this command sets the shutdown timeout in minutes.
9.4.31 Gets the shutdown timeout
•
Command syntax:
•
Command answer:
•
Command action:
•
Parameter range:
Description: this command retrieves the shutdown timeout in minutes.
9.4.32 Sets the VCP baud rate
•
Command syntax:
•
Command answer:
•
Command action:
•
Parameter range:
Description: this command sets the VCP baud rate.
R-PO7470 Manual – v. 1.1 – August 2008
".RT##"[CR]
[LF]
sets the reading timeout in seconds
##= 0 to 99.
"?RT##"[CR]
[CR][LF] "RT=##" [CR][LF]
gets the reading timeout in seconds
##= 0 to 99.
".ST#"[CR]
[LF]
sets the shutdown timeout in minutes
#= 1 to 9.
"?ST"[CR]
[CR][LF] "ST=#" [CR][LF]
gets the shutdown timeout in minutes
#= 0 to 9.
".SB#"[CR]
[LF]
sets the serial VCP baud rate.
#= 0 to 4.
0= 9600 baud
1= 19200 baud
2= 38400 baud
3= 57600 baud
4= 115200 baud