1 August 1988
2.2 ERASE LAMP UNIT REPLACEMENT
Turn off the main switch, and unplug the copier.
1.
2.
Open the front cover and remove the inner cover (1 E-ring, 5 screws).
3.
Remove the exposure glass (2 screws).
4.
Remove the lens cover [A] (2 screws).
5.
Open the clamshell and remove the master unit.
6.
Remove the erase lamp unit [B] (1 screw, 1 connector).
NOTE: When installing the erase lamp unit, make sure the cut-out in the
lamp fits over the metal tab (see illustration).
5-6