Configuring Probes for Health Monitoring
Command
Router(config-slb-probe)#
failed failed-interval
Router(config-slb-probe)# open
open-timeout
1. The no form of this command restores the defaults.
2. Inband health monitoring provides a more scalable solution if you are receiving performance alerts.

Configuring an HTTP Probe

An HTTP probe establishes an HTTP connection to a real server and then sends an HTTP request and
verifies the response. The probe probe-name http command places the user in HTTP probe
configuration submode.
To configure an HTTP probe, perform this task:
Command
Step 1
Router(config-module-csm)# probe
probe-name http
Step 2
Router(config-slb-probe-http)#
credentials username [ password ]
Step 3
Router(config-slb-probe-http)# expect
status min-number [ max-number ]
Catalyst 6500 Series Content Switching Module Configuration Note
9-4
Purpose
Sets the time between health checks when the server has been
marked as filed. The time is in seconds
Range = 2–65535
Default = 300 seconds
Sets the maximum time to wait for a TCP connection. This
command is not used for any non-TCP health checks (ICMP or
1
DNS
).
Range = 1–65535
Default = 10 seconds
Purpose
Configures an HTTP probe and enters the HTTP probe
1
submode
.
Configures basic authentication values for the HTTP SLB
1
probe
.
Configures a status code to expect from the HTTP probe.
You can configure multiple status ranges by entering one
expect status command at a time
min-number—If you do not specify a max-number, this
number is taken as a single status code. If you specify a
maximum number, this number is taken as the minimum
status code of a range.
max-number—The maximum status code in a range. The
default range is 0–999. (Any response from the server is
considered valid.)
If no maximum is specified, this command takes
Note
a single number (min-number). If you specify
both a minimum number and a maximum number,
it takes the range of numbers.
Chapter 9
Configuring Health Monitoring
1
.