Logic Menu; Motor Type - BFT THALIA P Installation Manual

Hide thumbs Also See for THALIA P:
Table of Contents

Advertisement

TABLE "B" - LOGIC MENU - (logic)
Logic
Definition

Motor type

MOTOR TYPE
(Set the type of motor
connected to the
board).
Automatic Closing
TCA
Time
FAST CLS.
Fast closing
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
PRE-ALARM
Pre-alarm
HOLD-TO-RUN
Deadman
Block pulses during
IBL OPEN
opening
Block pulses during
|IBL TCA
TCA
Block pulses during
IBL CLOSE
closing
Hammer during
RAM BLOW C. O P
opening
Hammer during
RAM BLOW C. C L
closing
BLOC PERSIST
Stop maintenance
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Motors not active
1
ELI 250 BT
2
PHOBOS BT
3
IgEA BT
0
 
4
LUX BT
5
LUX g BT
6
SUB BT
0
Logic not enabled
0
 
1
Switches automatic closing on
0
Logic not enabled
0
 
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as Start E, Start I,
0
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
0
 
Inputs configured as Start E, Start I,
2
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
 
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
0
 
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
2
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the sole-
0
 
1
noid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid
0
 
1
lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on
in the direction of the stop for approx. 3 seconds. This operation is performed every hour.
0
 
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil
1
due to a drop in temperature during extended pauses, such as during the night, or due to internal
leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURINg
CLOSINg
OPEN
CLOSES
CLOSES
DURINg
STOP + TCA STOP + TCA
OPENINg
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS
35
THALIA P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents