Logic
Definition
Configuration of
EXPI2 input
EXPI2
on input-output
expansion board.
Configuration of
EXPO2 output
EXPO1
on input-output
expansion board
Configuration of
EXPO2 output
EXPO2
on input-output
expansion board
TRAFFIC LIGHT
Traffic light pre-
flashing
PREFLASHING
TRAFFIC LIGHT
RED LAMP
Steadily lit red light
ALWAYS ON
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
associates the desired key with the 2nd radio channel command. Associates the desired key with the 2nd radio channel command. If no output
add 2ch
is configured as 2nd Radio Channel Output, the 2nd radio channel controls the pedestrian opening.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
38 -
THALIA P
Cross out
Default
setting
used
0
1
2
3
4
5
0
 
6
1-3
7
8
9
10
0
1
9
2
3
4-5
4
 
5
6
9
7
8
6-7
9
0
0
 
1
0
0
 
1
TORAUTOMATIC
Put
Lopaica
10020
ZAGREB
www.torautomatic.hr
info@torautomatic.hr
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Output configured as 2
Radio Channel.
nd
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Output configured as Alarm.
Output configured as Flashing light.
Output configured as Latch.
Output configured as Magnetic lock.
Output configured as Traffic Light control with TLB board.
Pre-flashing switched off.
Red lights flash, for 3 seconds, at start of operation.
Red lights off when gate closed.
Red lights on when gate closed.