7. Wiring.
CAUTION: Be sure outlet box is properly
grounded or that a ground wire (GREEN or Bare)
is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code. If you are unfamiliar with
electrical wiring or if the house/building wires
are different colors than those referred to below,
please use a qualified electrician.
Note: Excess lead wire length from the fan can be
cut to the desired length and then stripped.
When fan is secured in place on the hanging
bracket, electrical wiring can be made as
follows:
Connect BLACK and BLUE wires from fan to
BLACK wire from ceiling with wire connector
provided.
Connect WHITE wire from fan to WHITE wire
from ceiling with wire connector provided.
Connect all GROUND (GREEN) wires together
from fan to BARE/GREEN wire from ceiling
with wire connector provided.
If you intend to control the fan light with a
separate light switch, connect BLUE wire from
fan to the BLACK (or RED) supply from the
independent switch.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
8. Canopy Assembly.
Temporarily raise canopy to hanging bracket to
determine which 2 screws in hanging bracket
align with slotted holes in canopy, and then lower
canopy and partially loosen these 2 screws.
Remove the other 2 screws and set aside.
Now, lift canopy to hanging bracket again,
aligning slotted holes in canopy with loosened
screws in hanging bracket. Twist canopy to lock.
Re-insert the other 2 screws and secure all screws
with a Phillips screwdriver.
white supply wire
black supply wire
from ceiling
black
white
white
black
blue
from fan
canopy
page 6
ground
(green or bare)
ground
(green
or bare)
*
hanging bracket
slotted hole