Resetting Current Counters Of Pm (Rx & Tx) - Alcatel-Lucent 1675 LAMBDAUNITE Reference Manual

Multiservice
Hide thumbs Also See for 1675 LAMBDAUNITE:
Table of Contents

Advertisement

ES64U SNMP MIB description
....................................................................................................................................................................................................................................
Resetting current counters of PM (RX & TX)
Resetting the current counters will resume all the PM collection.
Limitation: In the 5.3 version the reset is done via re setting the ethAggrCDRxRow-
Status or ethAggrCDTxRowStatus as in
(p. 1-60)
9.3
Set
9.3
Set
....................................................................................................................................................................................................................................
1-62
IN ARG OpticIMCsgVar::AttrList
AttrList[0].instance[0] = interface ifIndex (ethernet type)
AttrList[0].oid = opticsIMETSMib:: ethAggrCDRxResetCounter
AttrList[0].type = INTEGER
AttrList[0].val = true (1)
IN ARG OpticIMCsgVar::AttrList
AttrList[0].instance[0] = interface ifIndex (ethernet type)
AttrList[0].oid = opticsIMETSMib:: ethAggrCDTxResetCounter
AttrList[0].type = INTEGER
AttrList[0].val = true (1)
Performance monitoring per port
Resetting current counters of PM (RX & TX)
"Creating collection of PM (RX & TX)"
365-374-201R11.0
Issue 1 July 2008

Advertisement

Table of Contents
loading

Table of Contents