755 series current/voltage tester
Table of Contents

Advertisement

2 Observe prior to use!

The instruction manual contains information and instructions which are
necessary for operating and using the instrument safely. Before using
the instrument, read the instruction manual carefully and comply with
all aspects of it. Keep this document to hand so that you can refer to it
when necessary. Forward this documentation to any subsequent users
of the instrument.
If the manual, the warnings and instructions are not followed, there is a
risk of life-threatening injuries to the user and damage to the
instrument.
Before using the fork meter in places with loud background noise,
make sure that the acoustic signal is discernible.

3 Safety instructions

The instrument may only be used by trained personnel. During all
operations, please observe the Employers' Liability Insurance
Association provisions for health and safety at work.
In order to prevent electric shock, take safety precautions when
working with voltages greater than 70 V (35 V) DC or 33 V (16 V)
rms. AC. These values are the limit for contact voltages in accordance
with DIN VDE (values in brackets apply to restricted areas, for example
agricultural sectors).
The instrument may only be touched at the designated grip areas, the
display elements must not be covered.
Maintenance work that is not described in this documentation must
only be carried out by trained service technicians.
If the instrument is modified in any way, operational safety can no
longer be guaranteed.
The fork meter must not be used while its battery compartment is open.
Batteries must be checked before use and changed if necessary.
If there is any battery leakage, the instrument must no longer be used
until it has been checked by our Customer Service.
The battery acid (electrolyte) is highly alkaline and electrically
conductive. Risk of acid burn! If the battery acid comes into contact
with your skin or clothing, thoroughly rinse the areas affected
immediately with plenty of water. If battery acid gets into your eyes,
rinse them immediately with plenty of water and seek medical advice.
Depending on the internal impedance of the voltage tester, there are
different ways of displaying "operating voltage present" or "operating
voltage not present" when interference voltage is present.
A voltage tester with relatively low internal impedance does not display
all interference voltages with an initial value above ELV, compared to
the reference value of 100 kOhm. Upon contact with the parts to be
tested, the voltage tester may temporarily reduce the interference
voltage by discharging to a level below ELV; however, after removing
the voltage tester, the interference voltage will assume its original value
once again.
If the notification "voltage present" does not appear, we strongly
recommend that you insert the earthing device before starting work.
A voltage tester with relatively high internal impedance will not clearly
display "operating voltage not present" in the event of existing
interference voltage, compared to the reference value of 100 kOhm.
If "voltage present" appears on a part which is considered
disconnected from the system, we strongly recommend that you