TESTO Saveris 2 Instruction Manual

TESTO Saveris 2 Instruction Manual

Wifi data logger system
Hide thumbs Also See for Saveris 2:

Advertisement

WiFi data logger system · testo Saveris 2
Instruction manual

Advertisement

Table of Contents
loading

Summary of Contents for TESTO Saveris 2

  • Page 1 WiFi data logger system · testo Saveris 2 Instruction manual...
  • Page 3: Table Of Contents

    Contents Contents ..................3 System ..................5 System overview ................. 5 First steps ..................6 Licences ..................6 testo Saveris 2 App ..............6 WiFi data logger ................8 Technical data ................8 5.1.1 Measurement-specific data ..........8 5.1.2 General data ................. 9 5.1.3...
  • Page 4 1 Contents User interface................23 Dashboard .................. 25 Measuring points ..............25 Active alarms ................25 Analysis & reports ..............25 Data analysis ................25 Automatic reports..............26 Alarms ..................27 Alarm list ................... 27 Alarm settings ................28 System warnings ..............29 Configuration ................
  • Page 5: System

    2 System System System overview The testo Saveris 2 WiFi data logger system is the modern solution for monitoring temperature and humidity values in storerooms and work rooms. The system consists of WiFi data loggers and a Cloud data storage system. The testo Saveris 2 WiFi data loggers record temperature and humidity reliably at adjustable intervals and transmit the readings directly to the Testo Cloud via WLAN.
  • Page 6: First Steps

    Quick Start Guide. Licences When purchasing your Saveris 2 system you will receive a free basic licence. Some measuring functions which are displayed in your Saveris 2 system are inactive. By expanding your licence you can activate and use these functions.
  • Page 7 Saveris 2 loggers correctly. You can also optionally create and send status reports. Alerts With the testo App, you can receive all Saveris 2 push alerts and see an overview. Purchase the testo Saveris 2 App This link will take you to the Google Play Store, where you can download the testo App onto your mobile terminal device free of charge.
  • Page 8: Wifi Data Logger

    1 °C (residual range) Not for condensing atmosphere. For continuous application in high humidity (> 80 %RH at ≤ 30 °C for > 12 h, > 60 %RH at > 30 °C for > 12 h), please contact us (www.testo-international.com).
  • Page 9: General Data

    5 WiFi data logger 5.1.2 General data WiFi data loggers Operating -30 to +50 °C temperature Storage -40 to +70 °C temperature (including batteries) Protection class IP 65 IP 65 IP 54 IP 30 IP 54 Measurement 1 min to 24 h (15 minutes default) rate Communication 1 min to 24 h (15 minutes default)
  • Page 10: Wifi-Specific Data

    5.1.4 Technical data for a secure wireless LAN Ports The testo Saveris 2 WiFi data loggers use the MQTT protocol, which communicates via port TCP 1883. These UDP port approvals are also required: • Port 53 (DNS name resolution) •...
  • Page 11: Authorizations

    DHCP or Static IP is used (select expert mode for the corresponding information) testo Saveris 2 application The testo Saveris 2 application is accessible via a normal, up-to- date browser (www). The standard TCP ports http (80) and https (443) are used.
  • Page 12: European Union, Efta Countries

    5 WiFi data logger 5.1.5.1 European Union, EFTA countries T1 (0572 2001):...
  • Page 13 5 WiFi data logger T2 (0572 2002):...
  • Page 14 5 WiFi data logger T3 (0572 2003):...
  • Page 15 5 WiFi data logger H1 (0572 2004):...
  • Page 16 5 WiFi data logger H2 (0572 2005):...
  • Page 17: Usa/Canada

    5 WiFi data logger 5.1.5.2 USA/Canada This instrument complies with Part 15C of the FCC Rules and Industry Canada RSS-210 (revision 8). Commissioning is subject to the following two conditions: (1) This instrument must not cause any harmful interference and (2) this instrument must be able to cope with interference, even if this has undesirable effects on operation.
  • Page 18: Korea

    Toi- Toi- Toi- Saveris2 Saveris2 Saveris2 Saveris2 Saveris2 Applicant Testo Instruments (Shenzen) Co., Ltd. Manufactu Testo Instruments (Shenzen) Co., Ltd. Country of China manufactu Note 해 해 무 무설 설 설운 운중전 전 전 전가 가 가 가있 있 5.1.5.7 Russia Authorized.
  • Page 19: Safety And The Environment

    Do not apply any force. • Only carry out maintenance and repair work on this instrument described in the documentation. Follow the prescribed steps exactly. Use only original spare parts from Testo. 5.2.2 Protecting the environment • Dispose of faulty rechargeable batteries/spent batteries in accordance with the valid legal specifications.
  • Page 20: Wall Bracket

    5 WiFi data logger Wall bracket The wall bracket ensures that the WiFi data logger is kept securely in place. Mounting materials are not included in the delivery. Select mounting materials that are appropriate for the required mounting location. Wall bracket with notches for mounting materials (screws or cable ties) Safety bolt Lock...
  • Page 21: Display And Control Elements

    Display Alarm LED, flashes red in the event of an alarm QR code, for direct access to the instrument data in the Testo Cloud Control key, to manually start data transfer Battery compartment (on rear) USB and probe sockets (on the bottom, instrument-...
  • Page 22: Display Icons

    WLAN signal strength 100% WLAN signal strength 75% WLAN signal strength 50% WLAN signal strength 25% Data connection to the Testo Cloud exists, icon flashes: Data connection to the Testo Cloud being established Alarm message Measurement channel 1 Measurement channel 2...
  • Page 23: User Interface

    6 User interface User interface System and status information (see page 36) Command bar (see page 36) User management (see page 35) Menu bar with the main menus: •...
  • Page 24 6 User interface Dashboard (see page 25) • Analysis & reports (see page 25) • Alarms (see page 27) • Configuration (see page 30) Display area...
  • Page 25: Dashboard

    8 Analysis & reports Dashboard The dashboard is the home page. It provides an overview of the key system data: Measuring points and Active alarms. Measuring points A summary of all measuring points is displayed. Click on the icon to display more information. Active alarms A summary of all active alarms and system warnings is displayed.
  • Page 26: Automatic Reports

    8 Analysis & reports Exporting readings and alarms (manually create a report) Filter the display so that the measuring points and time periods that you want to appear in the report are displayed. Click on the Export button and select the required output format (PDF or CSV).
  • Page 27: Alarms

    9 Alarms • Also send report via e-mail: as well as saving reports under Generated reports, these can also be sent as e- mails. Click on the checkbox to open the input screen for e- mail addresses. Click on the Create an automatic report button. The first report will be created on the following day.
  • Page 28: Alarm Settings

    9 Alarms On displaying the detailed information, the alarm message/system warning is marked as "read" and the alarm counter is marked down. Click on the Mark all as read button to mark all alerts as "read". Alarm settings Creating and displaying alarm settings •...
  • Page 29: System Warnings

    9 Alarms • E-mail recipient: addressees who are informed when an alarm occurs. Click on the checkbox in front of the recipient or enter the name and e-mail address of other recipients and click on the + Add button. • SMS recipient: addressees who are informed when an alarm occurs.
  • Page 30: Configuration

    Account Owner (name can be changed), with Administrator user role (role cannot be changed). • Testo Support (name can be changed), with Testo User Support user role (role cannot be changed). Creating and editing new users Other users with different User roles (see page 31) can be created and edited.
  • Page 31: User Roles

    10 Configuration • E-mail address & login: e-mail address of the user. The e- mail address is also the login name. The e-mail address is also used for system notifications (alarms, system warnings). • Change e-mail address & login (field is only available when editing the user account of the account holder): Enter a new e-mail address.
  • Page 32: Account Id

    10.3 Account ID The Account ID is the unique address of your user account in the Testo Cloud. This is needed to configure the WiFi data loggers in order to ensure that they send your data to the correct user account.
  • Page 33: Areas

    10 Configuration The following settings can be defined and edited: • Title: designation of the measuring point group (required field). • Description: description of the measuring point group. • Area: area that the measuring point group is to be assigned to. •...
  • Page 34: Wifi Data Loggers

    • Day communication cycle and Night communication cycle: interval at which readings are transmitted to the Testo Cloud. Select the start time for the day communication cycle and the night communication cycle. Set the communication cycle using the slide control.
  • Page 35: Firmware Updates

    • Save click on the button to save the settings. 11.2 Account information Information about your Saveris 2 account is displayed. 11.3 Change password The user password can be changed. New password and New password (repeat): enter new password in both text fields.
  • Page 36: Command Bar

    13 System and status information 12 Command bar 12.1 Open Quick Start Guide The Quick Start Guide can help you with logging in WiFi data loggers. • Click on the icon to open the Quick Start Guide. 12.2 Open Online Help The Online Help (this document) provides support for issues related to the product components.
  • Page 38 0970 4041 en 06...

Table of Contents