Output Timing Characteristics

Parameter
Output Low Voltage
Output High Voltage
Output Threshold High Voltage
Output Threshold Low Voltage
Cycle Rise Time
Cycle Fall Time
Opto Current
Opto Isolator Delay (High to Low)
Opto Isolator Delay (Low to High)
10/27/2017
©2017 FLIR Integrated
Imaging Solutions Inc.
All rights reserved.
Note: Timing specifications are preliminary and subject to
change.
Output Timing Characteristics
Opto-isolated Output Performance at (measured at Vcc = 5 V, Rext = 1 kΩ)
Symbol
V
L
V
H
V
THH
V
THL
t
R
t
F
Opto-isolated at 1 FPS
0.84 V
4.98 V
4.56 V
1.25 V
7.9 µs
2.1 µs
3.8 mA
2.92 µs
24.2 µs
®
FLIR Oryx
Installation Guide
7 Input/Output Control
Opto-isolated at 90 FPS
0.83 V
4.98 V
4.56 V
1.24 V
7.8 µs
1.44 µs
3.8 mA
2.92 µs
24.2 µs