ISTRUZIONI PER L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCTIONS DE MISE EN SERVICE ET D'ENTRETIEN
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE
INSTALLATIONSANWEISUNG UND WARTUNG
INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD
POKYNY K INŠTALÁCII A ÚDRŽBE
ИНСТРУКЦИИ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ БСЛУЖИВАНИЮ
KULLANIM VE BAKIM TALİMATLARI
INSTALLATIONS - OCH UNDERHÅLLSANVISNING
INSTRUCCIONES PARA LA INSTALACIÓN Y EL MANTENIMIENTO
INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO
POKYNY K INSTALACI A ÚDRŽBĚ
ASENNUS- JA HUOLTO-OHJEET
INSTRUCTIUNI DE INSTALARE SI INTRETINERE
INSTRUKCJA MONTAŻU I KONSERWACJI
安装和维护说明
.ª¦Bl{A¥ J¦yZK{{ LAXBcZG
FEKA VS
FEKA VX
DRENAG 1000-1200

Advertisement

loading

Summary of Contents for DAB FEKA VS

  • Page 1 INSTRUCCIONES PARA LA INSTALACIÓN Y EL MANTENIMIENTO INSTRUÇÕES PARA A INSTALAÇÃO E A MANUTENÇÃO POKYNY K INSTALACI A ÚDRŽBĚ ASENNUS- JA HUOLTO-OHJEET INSTRUCTIUNI DE INSTALARE SI INTRETINERE INSTRUKCJA MONTAŻU I KONSERWACJI 安装和维护说明 .ª¦Bl{A¥ J¦yZK{{ LAXBcZG FEKA VS FEKA VX DRENAG 1000-1200...
  • Page 2: Table Of Contents

    Einstellen des Schwimmerschalters Precautions Vorsichtsmaßnahmen Maintenance and cleaning Wartung und Reinigung Checking and changing the oil FEKA VS-VX Kontrolle und Ölwechsel FEKA VS-VX Checking and changing the oil DRENAG 1000-1200 Kontrolle und Ölwechsel DRENAG 1000-1200 Modifications and spare parts Änderungen und Ersatzteile Troubleshooting Störungssuche und Abhilfen...
  • Page 3: Technical Data And Limits On Use

    APPLICATIONS The FEKA VS-VX pump is a submersible centrifugal pump made of stainless steel with a vortex back impeller, designed and built for use with dirty water from septic tanks and dirty water in general containing solid bodies with maximum diameter 50 mm, but only for non-aggressive water.
  • Page 4: Installation

    Totally immerse the pump in the water. INSTALLATION FEKA VS-VX 700x700 1. On the version provided with a float switch, ensure that the float can move freely (SEE THE PARAGRAPH ON ADJUSTING THE FLOAT SWITCH).
  • Page 5 ENGLISH 3. Connect the delivery pipe or hose directly to the pump mouth. If the pump is used in fixed installations it is advisable to connect it to the pipe with a coupling so as to facilitate disassembly and reinstallation. If a hose is used, fit a threaded hosetail on the pump mouth. Wrap the thread with suitable material to ensure an effective seal (teflon tape or similar).
  • Page 6: Starting Up

    ENGLISH 3. When the pump is to be in a fixed installation, with a float, a check valve must always be fitted in the delivery pipe. This is also advisable on pumps with manual operation. ELECTRIC CONNECTION CAUTION! ALWAYS FOLLOW THE SAFETY REGULATIONS. 1.
  • Page 7: Maintenance And Cleaning

    ENGLISH Ensure that the stop level does not uncover the strainer. (Fig.5) PRECAUTIONS 1. The intake strainer must always be in place during pump operation. 2. The pump should not be started more than 20 times in one hour so as not to subject the motor to excessive thermal shock.
  • Page 8 ENGLISH CHECKING AND CHANGING THE SEALING OIL FEKA VS-VX To perform this operation, slacken the six screws (45) so as to be able to remove the strainer cover , the strainer and the pump body (1). Retain the O-ring (28) and the nuts (51).
  • Page 9 ENGLISH CHECKING AND CHANGING THE SEALING OIL DRENAG 1000-1200 To perform this operation you must unscrew the six screws of the flange (45) so as to be able to remove the flange (105) and the outer jacket (77). Unscrew the three screws of the filter cover (136) and remove the cover (92) and the filter (42).
  • Page 10: Start

    ENGLISH MODIFICATIONS AND SPARE PARTS Any modification not authorized beforehand relieves the manufacturer of all responsibility. All the spare parts used in repairs must be original ones and the accessories must be approved by the manufacturer so as to be able to guarantee maximum safety of the machines and systems in which they may be fitted.
  • Page 11 /Modell / Model /Modelo Modell / Model / Модель QY¥} / Malli / Model Hmax (m) 2 poles 50 Hz Hmax (m) 2 poles 60 Hz FEKA VS 550 FEKA VS 750 FEKA VS 1000 11.8 11.8 FEKA VS 1200 15.2...
  • Page 12 Tel.: +32 2 4668353 Tel.: +31 416 387280 Fax: +32 2 4669218 Fax: +31 416 387299 PUMPS AMERICA, INC. DAB PUMPS DIVISION DWT South Africa 3226 Benchmark Drive Podium at Menlyn, 3rd Floor, Unit 3001b, Ladson, SC 29456 USA 43 Ingersol Road, C/O Lois and Atterbury, info.usa@dwtgroup.com...

This manual is also suitable for:

Feka vxDrenag 1000Drenag 1200