CAME AMICO Series Installation Manual

Automation for swing gates
Hide thumbs Also See for AMICO Series:

Advertisement

Quick Links

AUTOMATION FOR SWING GATES
INSTALLATION MANUAL
A18230
EN
English

Advertisement

Table of Contents
loading

Summary of Contents for CAME AMICO Series

  • Page 1 AUTOMATION FOR SWING GATES INSTALLATION MANUAL A18230 English...
  • Page 2: Read Carefully

    Warning Sings (e.g. gate plate). (i.e. that for which it was expressly built for). Any other use is Special instructions and to be considered dangerous. Came Cancelli Automatici S.p.A. advice for users is not liable for any damage resulting from improper, wrongful •...
  • Page 3: General Conditions Of Sale

    3. ORDERS The sale agreement is executed once the written order is confirmed by Came Cancelli Automatici Spa or when the order is fulfilled by the company. Orders that are addressed, and signed by clients, to Came Cancelli Automatici SpA are deemed to be firm and irrevocable for 30 days starting from the date they are received by the company.
  • Page 4: Legend Of Symbols

    200 kg 3 Reference Standards The company CAME cancelli automatici s.p.a. is ISO 9001:2000 quality certified; it has also obtained the ISO 14001 environmental safeguarding certification. Came engineers and manufactures all of its products in Italy. This product complies with the following standards: EN 12978, UNI EN 954-1, CEI EN 60335-1, UNI EN 12453.
  • Page 5: Description Of Parts

    4.3 Description of parts A1824 1) Operator 2) Pilaster bracket 3) Gate bracket 4) Screw, bushing and nut for the pilaster bracket 5) Bolt and nut for the gate bracket 6) Pin distancer 4.4 Dimensions (mm) 5 Installation Installation must be carried out by expert qualified personnel and in full compliance with current regulations. 5.1 Preliminary checks Before installing, do the following: •...
  • Page 6: Tools And Materials

    5.2 Tools and materials Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer. 5.3 Cable list and minimum thickness Length of cable Length of cable...
  • Page 7: Installing The Operator

    5.5 Installing the operator The following illustrations are only examples, given that the space available for anchoring the operator and accessories may vary from gate to gate. It is up to the installer, thus, to choose the most suitable solution. Lay the corrugated tubing needed for the connections deriving from the junction box.
  • Page 8 Assemble and weld the two parts of the pillar bracket. Secure the bracket to the point you have chosen with proper plugs and screws or - if the pillar is made of metal - weld it on. Weld the gate bracket to the gate leaf making sure the quotas shown in the table are met. Note: on non-metal gate leaves assemble and weld the two parts of the bracket and secure them with proper screws.
  • Page 9 Insert the bushing onto the main lug as shown in the drawing. Bushing Open the gate leaf, insert the faceted anchoring lug into the slotted hole in the head bracket and tighten it using the (1) issued washer and nut or, alternatively, release the gearmotor (see manual release paragraph), remove the head cover and move the faceted anchoring lug using a screwdriver until it lines up with the slotted hole, then secure it.
  • Page 10: Connecting To The Control Panel

    5.6 Connecting to the control panel For the electrical connection procedures, use the junction box and branching boxes. Connecting the 230V a.c. delayed closing gearmotor ZA3N Control panel Connecting the 230V a.c. delayed opening gearmotor Power 230V a.c. - 50/60 Hz 5.7 Outward opening installation Opening (mm)
  • Page 11 Gate bracket Pillar bracket Extra bracket Remove the mechanical opening stop and position it at the far end. Open the gate to the max opening position, place the mechanical stop against it with the pin attachment and fi x it in place. Connect the gearmotors to the panel as shown in the diagram.
  • Page 12: Safety Instructions

    5.8 Manual release of the gearmotor Slide open the small door that protects the release, insert the tri-lobed key and turn it. 6 Safety instructions Important safety instructions This product must only be employed for its originally intended use. Any other use is wrong and potentially dangerous. The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses.
  • Page 13: Maintenance

    7 Maintenance 7.1 Periodic maintenance Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells; check that the safety devices work properly; remove any obstructions. We suggest checking the state of lubrication and tightness of the anchoring screws on the operator. To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing.
  • Page 14: Extraordinary Maintenance

    Periodic maintenance log for end-user (every 6 moths) Date Notes Signature 7.3 Extra-ordinary maintenance The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms. N.B.: Any extraordinary maintenance must be performed by specialised technicians. Extra-ordinary maintenance log Installer’s stamp Operator name...
  • Page 15: Phasing Out And Disposal

    CAME Cancelli Automatici S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system at its plants, to ensure that environmental safeguarding. We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market operations strategies, by simply following these brief guidelines when disposing.
  • Page 16 (+7) 495 739 00 69 (ext. 226) (+44) 115 9210431 CAME GROUP Benelux S.a. CAME GROUP Benelux S.a. CAME (Shanghai) Automatic Gates Co. Ltd. CAME (Shanghai) Automatic Gates Co. Ltd. Zoning Ouest 7 1st Floor, Building 2, 7860 Lessines - Lessines - BELGIUM No.

This manual is also suitable for:

A18230

Table of Contents