Register Write
0x0210
No
0x0211
No
0x0212
No
0x0213
No
0x0214
No
0x0215
No
0x0216
No
0x0217
No
0x0218
No
0x0219
No
0x021A
No
0x021B
No
0x021C
No
0x021D
No
0x021E
No
0x021F
No
0x0220
No
0x0221
No
0x0222
No
0x0227
No
0x0228
No
0x0229
No
0x022A
No
0x022B
No
0x1004
Yes
32
User's manual for
Range
-
Door width in pulses, high byte
-
Door width in pulses, low byte
200 ÷ 3999 „Width"
10 ÷ 399
„Weight"
0 ÷ 79
„V opening"
0 ÷ 79
„V closing"
50 ÷ 999
„Init. speed "
-
Acceleration/deceleration speed of door opening
-
Acceleration/deceleration speed of door closing
-
Start point of deceleration while opening in [mm]
-
Start point of deceleration while closing in [mm]
0 ÷ 299
„Lock zone" parameter in „Calibration" menu, in [mm]
„OPENING inp." parameter in „Inputs" menu:
0 ÷ 1
0 – inactive; 1 - active;
„CLOSING inp." parameter in „Inputs" menu:
0 ÷ 1
0 – inactive; 1 - active;
„OPEN switch" parameter in „Calibration" menu:
0 ÷ 1
0 – inactive; 1 - active;
„OPEN output" parameter in „Outputs" menu:
0 ÷ 2
0 – inactive; 1 - normal open; 2 - normal closed
„CLOSED outp." parameter in „Outputs" menu:
0 ÷ 2
0 – inactive; 1 - normal open; 2 - normal closed
„BARRIER out." parameter in „Outputs" menu:
0 ÷ 2
0 – inactive; 1 - normal open; 2 - normal closed
„External" parameter in „Photocell" menu:
0 ÷ 2
0 – inactive; 1 – transfer; 2 - active
„INSTALL inp." parameter in „Inputs" menu:
0 ÷ 1
0 – inactive; 1 - active;
-
Additional input (not used)
„Language" parameter in „Region" menu:
0 ÷ 1
0 – Polish; 1 - English;
„Lock. speed" parameter in „Calibration" menu:
0 ÷ 5
0 – MIN.; 1 – 20% ... 5 – 100%
0 ÷ 99
„Force reduc."
Write only register, allows to door control while RS-485 mode:
see desc.
0 – open, 0x100 – close,
elevator door controller
Register description
parameter in
„Doors data" menu, in [mm]
parameter in
„Doors data" menu, in [kg]
parameter in
„Speeds" menu, in [cm/s]
parameter in
„Speeds" menu, in [cm/s]
parameter in
„Calibration" menu, in [0.1%]
parameter in
SDK-500
„Calibration" menu, in [%]