4.4. MENU DESCRIPTION

1. Doors data

1.1. Width, range: 20.0 ÷ 399.9 [ cm ]
The real (measured) path of a single-slide of door must be entered here. For single-slide
door the entire door width must be entered. For double slide door (build with two separate
parts meeting in the centre) a half of the entire door width must be entered. Entering incorrect
value will lead to incorrect calculation of the real door speed, which is necessary to stay in line
with value entered to the menu.
1.2. Weight, range: 10 ÷ 399 [ kg ]
It is mandatory to enter real door weight. It is critical to control of door's kinetic energy,
whose maximum value must not exceed 10 J.
CAUTION! Entering incorrect values can lead to the faulty operation of the door
and/or can create serious risk of injuries.
If the door weight setting is being changed after the speed settings have been
made and a value is entered which would result in exceeding the maximum
allowable kinetic energy of the door, the controller will display "Kinetic energy
exceeded" message and automatically adjust maximum speed such as to
account for the new weight setting.

2. Speeds

2.1. V Opening, range: 0.10 ÷ 0.79 [ m/s ]
Required door opening speed should be entered here.
2.2. V Closing, range: 0.10 ÷ 0.79 [ m/s ]
Required door closing speed should be entered here.
Based on the entered door weight SDK-500 automatically calculates maximum door
speed not to exceed the maximum allowed kinetic energy of the door (10J). If the V Opening
or V Closing entered here is greater than the calculated maximum speed, it will be adjusted
down to prevent of exceeding the maximum value of kinetic energy.
If the door weight setting is changed by the installer (operator) such that the
kinetic energy calculated for speed V Opening or V Closing exceeds the
permissible value then "Kinetic energy exceeded", message is displayed. In
this case adjustments are made automatically to V Opening or V Closing or
both to bring the kinetic energy down to its maximum value.
CAUTION! Subsequent change of door weight setting back to original value
WILL NOT affect the V Opening or V Closing values. It is necessary to enter
required values again.