5.2. WARNING MESSAGES

While normal operation and menu parameters configuration some warning messages
described below can appear on the display.
When motor driver is overheated the message
„Exceedance
alternately to current screen.
If the average current value of opening+closing
cycle is higher than maintenance current value I
(described at page 22) then present screen will be
displayed
alternately
message.
If the parameter „Access pass." was set to the
value other then 000000, then password is required
before entering menu. There is „Enter password"
message displayed to remind about it.
In case of wrong password entering "Wrong
Password!" message is displayed.
In case your password is forgotten please contact
TechWind to receive new – one use password.
Once the one use password is entered the message
„Enter new password!" is displayed. User must
enter new password. This operation can not be
omitted.
All menu parameters have their range which can be
entered. If the value out of range is entered
„Incorrect Value" message is displayed and edit
function is continued.
Controller checks the allowed limit of the maximum
kinetic
energy,
„V opening" or „V closing" are changed in the
menu. If the opening /closing speed is to high for
the door weight then speed is automatically reduced
to value corresponding to maximum allowed value
of kinetic energy. (Ekmax<10J). In such a case
message „Exceedance of kinetic energy" and
next „Speed is decreased !"
28
User's manual for
of
temperature"
to
the
„Need
once
parameter
elevator door controller
is
displayed
M
service"
„Weight" ,
SDK-500
Exceedance of
temperature
Need service
Enter Password
Wrong Password!
Enter new password!
Incorrect Value
Exceedance of
kinetic energy
Speed is
decreased !