4. Working modes

4.1. Driver mode, options: [ RS-485 lines / external inputs / automatic / manual ]
SDK-500
The
elevator control systems. To provide proper connection to different types of main controllers,
correct menu option must be chosen:
RS-485 lines
„ external inputs " - systems control using separate {CLOSE INP.} and
automatic
manual
4.2. Door number, range: 0 ÷ 3
Used in multi-door installation. It corresponds to the address of the
and is used in systems driven by RS-485 interface ONLY .

5. Inputs

5.1 OPENING inp. (OPENING input), options: [ inactive / active ]
Voltage controlled input. Receives signals from the main elevator controller. If
{OPEN INP.} input is set to 'active', then signal on this input will open the door. If
{CLOSE INP.} input (see "CLOSING inp." parameter description) is set to 'inactive', then
removing the signal will close the door.
5.2 CLOSING inp. (CLOSING input), options: [ inactive / active ]
Voltage controlled input. Receives signals from the main elevator controller. If
{CLOSE INP.} input is set to 'active', then signal on this input will close the door. If
{OPEN INP.} input (see "OPENING inp." parameter description) is set to 'inactive', then
removing the signal will open the door.
It is not advisable to set {OPEN INP.} to inactive and {CLOSE INP.} to active.
Such settings may cause malfunction of the door if electrical wiring of these
inputs becomes damaged.
User's manual for
controller is designed as a universal unit to be used with various 3
" - systems control using RS-485 communication bus and
ModBus RTU protocol. It is required to provide proper data
transmission format and registers addresses.
{OPEN INP.} inputs.
" - automatic closing and opening option is used for service
purposes only. It allows for automatic opening and closing
door. Once it is selected doors are opening and closing every
5 second ignoring any external signals.
" - after setting this option and leaving the menu, each [ENTER]
pressing will close and open doors alternately.