User's Manual For Elevator Door Controller Sdk - TechWind SDK-500 User Manual

Elevator door controller
Table of Contents

Advertisement

line1:
door position in cm
line2:
pulses counter value
SCREEN 4
line1:
average current value of opening+ closing
cycle in A
line2:
maximal current value of opening / closing
operation in A
SCREEN 5
line1
power supply voltage in V
line2:
battery power supply in V
SCREEN 6
line1:
tightening force (current) of closed door in
line2:
A
tightening force (current) of open door in
A
SCREEN 7
line1:
door closing current (force) in A
line2:
door opening current (force) in A
SCREEN 8
line1:
present temperature of the controller
executable components in °C
line2:
permissible temperature of the controller
executable components in °C
SCREEN 9
line1:
control inputs state, in order: {OPEN
INP.}, {CLOSE INP.}, {END SWITCH},
{INSTALL} , {EXT. BARRIER}
relay outputs state, in order:
line2:
{BARRIER} , {CLOSED} , {OPEN} and
battery power supply switch state
User's manual for
elevator door controller
SDK-500
Posit.:
67cm
Counter:
30150
av.cur.:
0.50A
m. cur.:
2.10A
Power:
24.0V
Battery:
21.3V
Tight.c:
0.30A
Tight.o:
0.60A
C.force:
2.00A
O.force:
2.80A
Temper.:
26`C
T. max.:
120`C
Inputs:
00001
Outputs:
000 0