Figure 3.10 shows connections of an Installation switch to {INSTALL} input of the SDK-
500. The Installation switch can be mounted on the housing of the SDK-500 in order to
perform „Installation" procedure without the need to enter the controller's menu. If the
{INSTALL} input is activated for a few seconds the SDK-500 will enter the „Installation"
procedure (see page 19).
CAUTION!
Before {INSTALL} switch can be used, the door parameters must be entered to
the controller using menu.
{INSTALL} input is enabled by default.

3.10. OPTIONAL TERMINAL POSITION CONTACT (DOOR OPEN)

Figure 3.11 shows the connection of the optional terminal position contact (NO type
contact connected to the {END SWITCH} input) to indicate the full opening of the door. Use of
such contact is optional as the SDK-500 detects the terminal positions of door by detecting the
mechanical resistance at its terminal positions. This {END SWITCH} input is provided for
compatibility of SDK-500 with the widest range of doors and control systems.
CAUTION!
Remember to activate {END SWITCH} input in the controller's menu (see OPEN
switch parameter description at page 21).
User's manual for
J9
J8
Fig. 3.11. Optional terminal position contact connection
elevator door controller
2
+15V
1
5
4
3
2
END SWITCH
1
SDK-500