Buffalo TeraStation 5010 TS5210DN User Manual page 203

Table of Contents

Advertisement

LCD Message
I32 New Drive x
Detected
I33 Replication
Failure
I34 Virus
Quarantined
I37 Recovering
System...
I38 Recovery
Finished
I40 All Data Will Be
Deleted
I41 Push Func to
Start Recovery
I42 Preparing
Recovery
I43 Unsupported
Hardware
I44 Drive 1 Not
Found
I45 Recovery Failed
I46 Migrating RAID
Array x...
I47 Don't Power Off
System!
I48 Push Func to
Start Failover
I49 Lost Failover
Main
I50 Failover in
Maintenance Mode
I51 Initializing
Failover...
I52 New Firmware
Available
Description
Displays after replacing the drive when
the RAID needs to be rebuilt in Settings or
formatting is necessary.
An error occurred in replication, or
synchronization between the main
TeraStation and the backup TeraStation
failed during failover configuration.
A virus scan found a virus.
Settings initialization in progress.
Settings initialization is complete.
Beginning settings initialization. All data
on the drive 1 will be deleted.
Press the function button on the front to
start the settings initialization process.
Preparing to start the settings initialization
process.
The TeraStation was started from the
USB initialization device, but the settings
cannot be initialized from this USB
initialization device.
Initialization from the USB initialization
device was initiated, but drive 1 was not
detected.
Initialization failed.
Data migration or conversion (RAID
migration) is in progress.
This TeraStation is ready to become the
failover backup for the main TeraStation.
The main TeraStation in the failover
configuration cannot be found.
Failover maintenance is in progress.
Initializing the failover configuration.
A new firmware version has been released.
Corrective Action
In Settings, either rebuild the RAID array or
format the drive.
In Settings, navigate to Backup -
Replication and click Resync to execute
resynchronization.
If you configured the subfolders' access
restrictions to be inherited to the
replication or failover destinations, disable
them or change the destinations.
If the error is displayed again, contact
Buffalo technical support for assistance.
Once the virus is removed from the
quarantine folder, the message is no
longer displayed. If the antivirus software
is configured to delete viruses from the
quarantine folder automatically, then the
message will not be displayed.
-
-
-
-
-
-
Make sure that drive 1 is present and fully
inserted in its slot.
-
Do not turn off the TeraStation's power.
Hold down the function button on the
front of the target TeraStation until it stops
beeping to accept failover backup status.
Make sure that the main TeraStation is on,
working, and connected to the network.
Do not turn off the TeraStation's power.
Do not turn off the TeraStation's power.
Update the firmware.
202