Radware Alteon Installation And Maintenance Manual page 79

Next-generation application delivery controller
Hide thumbs Also See for Alteon:
Table of Contents

Advertisement

Table 14: General Specifications of Alteon Application Switch 4408 and 4416 Platforms
Item
Alteon Application Switch 4408
(and 4408 XL)
Auto-range
AC:
supply
100V–240V
Frequency: 47Hz–63Hz
DC: –36V~–72V
Dual power supply (AC/DC) for relevant models
Power
Single power supply: 175 W,
consumption
195 W
Dual power supply: 140 W, 157 W
Power Supply
Dual power supply (AC/DC) is
Option
optional.
Heat dissipation
Single power supply: 597 BTU/h.
665 BTU/h (XL)
Dual power supply: 477 BTU/h,
535 BTU/h (XL)
Certifications
Safety: EN 60950-1:2006, CB - IEC# 60950-1, CCC i , cTUVus
EMC: C-Tick, CE, FCC Part 15B Class A, ICES-003, EN 55022, EN 55024,
VCCI Class A ii , KCC
RoHS 6 Compliant
CPU temperature SNMP traps are sent in response to
high temperatures:
Warning: 74º C
Critical: 81º C
i – For single power-supply units only.
ii – Except for single DC power-supply units.
Table 15: General Specifications of Alteon Application Switch 5224 and 5224 XL Platforms
Item
Alteon Application Switch 5224
Nominal
Dependent on throughput license:
throughput
1 Gbps
2 Gbps
4 Gbps
8 Gbps
12 Gbps
16 Gbps
ADC-VX
With 12 GB RAM, up to 10 instances
specialized ADC
With 24 GB RAM, up to 24 instances
Hypervisor
running virtual
ADC instances
Document ID: RDWR-ALOS-V2815_IG0203
Radware Alteon Installation and Maintenance Guide
Alteon Application Switch 4416 (and 4416
XL)
Single and Dual power supply:270 W
Single and Dual power supply:304 W (XL)
Dual power supply (AC/DC) is optional and
comes as 2U.
Single and Dual power supply: 921 BTU/h
Single and Dual power supply (XL): 1037
BTU/h
SNMP traps are sent in response to high
temperatures:
Warning: 69º C
Critical: 74º C
Alteon Application Switch 5224 XL
Specifications
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents