INTERCONNECTION OF UNITS
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified type DP-1 or
DP-2. (Note- when residing in non LPS circuit)
OVERCURRENT PROTECTION
A readily accessible listed branch-circuit over current protective device rated 15 A must be
incorporated in the building wiring for each power input.
REPLACEABLE BATTERIES
If equipment is provided with a replaceable battery, and is replaced by an incorrect battery type,
then an explosion may occur. This is the case for some Lithium batteries and the following is
applicable:
If the battery is placed in an Operator Access Area, there is a marking close to the battery or
a statement in both the operating and service instructions.
If the battery is placed elsewhere in the equipment, there is a marking close to the battery or a
statement in the service instructions.
This marking or statement includes the following text warning:
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT BATTERY TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Caution – To Reduce the Risk of Electrical Shock and Fire
1. This equipment is designed to permit connection between the earthed conductor of the DC
supply circuit and the earthing conductor equipment. See Installation Instructions.
2. All servicing must be undertaken only by qualified service personnel. There are not user
serviceable parts inside the unit.
3. DO NOT plug in, turn on or attempt to operate an obviously damaged unit.
4. Ensure that the chassis ventilation openings in the unit are NOT BLOCKED.
5. Replace a blown fuse ONLY with the same type and rating as is marked on the safety label
adjacent to the power inlet, housing the fuse.
6. Do not operate the device in a location where the maximum ambient temperature exceeds
40°C/104°F.
7. Be sure to unplug the power supply cord from the wall socket BEFORE attempting to remove
and/or check the main power fuse.
CLASS 1 LASER PRODUCT AND REFERENCE TO THE MOST RECENT LASER STANDARDS IEC 60
825-1:1993 + A1:1997 + A2:2001 AND EN 60825-1:1994+A1:1996+ A2:2001
AC units for Denmark, Finland, Norway, Sweden (marked on product):
Denmark - "Unit is class I - unit to be used with an AC cord set suitable with Denmark
deviations. The cord includes an earthing conductor. The Unit is to be plugged into a wall socket
outlet which is connected to a protective earth. Socket outlets which are not connected to earth
are not to be used!"
Finland - (Marking label and in manual) - "Laite on liitettävä suojamaadoituskoskettimilla
varustettuun pistorasiaan"
Norway (Marking label and in manual) - "Apparatet må tilkoples jordet stikkontakt"
Unit is intended for connection to IT power systems for Norway only.
Sweden (Marking label and in manual) - "Apparaten skall anslutas till jordat uttag."
To connect the power connection:
1. Connect the power cable to the main socket, located on the rear panel of the device.
2. Connect the power cable to the grounded AC outlet.
Document ID: RDWR-ALOS-V2815_IG0203
Radware Alteon Installation and Maintenance Guide
11