Line distance protection REL650 2.2
Product version: 2.2.1
Binary input/output modules
For pulse counting, for example kWh metering, the BIM with enhanced pulse counting capabilities must be used.
Note: 1 BIM required in position P3 and 1 BOM always included in position P4.
Slot position (front view/rear view)
1/2 case with 1 TRM
Compression terminals
No board in slot
Binary output module 24 output relays (BOM)
BIM 16 inputs, RL24, 24-30VDC, 50mA
BIM 16 inputs, RL48, 48-60VDC, 50mA
BIM 16 inputs, RL110, 110-125VDC, 50mA
BIM 16 inputs, RL220, 220-250VDC, 50mA
BIM 16 inputs, RL220, 220-250VDC, 120mA
BIM 16 inputs, RL24, 24-30VDC, 50mA, enhanced pulse counting
BIM 16 inputs, RL48, 48-60VDC, 50mA, enhanced pulse counting
BIM 16 inputs, RL110, 110-125VDC, 50mA, enhanced pulse
counting
BIM 16 inputs, RL220, 220-250VDC, 50mA, enhanced pulse
counting
IOM 8 inputs, 10+2 outputs, RL24, 24-30VDC, 50mA
IOM 8 inputs, 10+2 outputs, RL48, 48-60VDC, 50mA
IOM 8 inputs, 10+2 outputs, RL110, 110-125VDC, 50mA
IOM 8 inputs, 10+2 outputs, RL220, 220-250VDC, 50mA
IOM 8 inputs 10+2 outputs, RL220, 220-250VDC, 110mA
IOM with MOV 8 inputs, 10+2 outputs, RL24, 24-30VDC, 50mA
IOM with MOV 8 inputs, 10+2 outputs, RL48, 48-60VDC, 50mA
IOM with MOV 8 inputs, 10+2 outputs, RL110, 110-125VDC, 50mA
IOM with MOV 8 inputs, 10+2 outputs, RL220, 220-250VDC, 50mA
Station communication and time synchronization
Slot position (front view/rear view)
Available slots in 1/2 case with 1 TRM
No communication board included
Ethernet SFP, optical LC connector
Ethernet SFP, RJ45 connector
Serial SPA/LON/DNP/IEC 60870-5-103 plastic
interface
Serial SPA/LON/DNP/IEC 60870-5-103 plastic/
glass interface
Serial SPA/LON/DNP/IEC 60870-5-103 glass
interface
Galvanic RS485 communication module
Line data communication, default 64kbps mode
IRIG-B time synchronization module
ABB
Ordering no
1MRK002960-KA
1MRK000614-AB
1MRK000508-DD
1MRK000508-AD
1MRK000508-BD
1MRK000508-CD
1MRK000508-CE
1MRK000508-HA
1MRK000508-EA
1MRK000508-FA
1MRK000508-GA
1MRK000173-GD
1MRK000173-AE
1MRK000173-BE
1MRK000173-CE
1MRK000173-CF
1MRK000173-GC
1MRK000173-AD
1MRK000173-BD
1MRK000173-CD
Selection for
position #10
Ordering no
X
1MRK005500-AA
K
K
1MRK005500-BA
P
P
1MRK001608-AB
1MRK001608-BB
1MRK001608-CB
1MRK002309-AA
1MRK002305-AA
Selection for
K
position #11
#10
C
X
A
A
B1
B1
C1
C1
D1
D1
E1
E1
E2
E2
F
G
H
K
L1
M1
N1
P1
P2
U
V
W
Y
C
#11
X
X
X
X
X
X
K
K
P
P
L
M
N
G
F
1MRK 506 384-BEN A
Notes and rules
Max 3 positions in 1/2 rack
Notes and rules
X
X
Ethernet SFP is basic in
P30:1.
G
X
LDCM is not applicable.
F
X
85