Technical Specifications - Gallagher T15 Mifare Reader Black Installation Note

Hide thumbs Also See for T15 Mifare Reader Black:
Table of Contents

Advertisement

7
Technical specifications
Routine maintenance:
Cleaning:
Voltage:
Current:
Temperature range:
Humidity:
Environmental protection:
Impact rating:
Unit dimensions:
Maximum number of readers
on one HBUS cable:
The reader is idle.
1
Peak current during card read.
2
Gallagher T Series readers are UL humidity tested and certified to 85% and have been independently
3
verified to 95%.
Note: The current values stated above have been reported using the default configuration for a reader
in Command Centre. Changing the configuration may vary the current value.
3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited
Not applicable for this reader
This reader should only be cleaned with a clean, lint free, damp cloth
9 Vdc - 16 Vdc
Mifare Reader
Idle
1
at 9 Vdc
124 mA
at 13.6 Vdc
84 mA
-35 °C to +70 °C
Note: Direct sunlight may increase the internal reader temperature
above the ambient temperature level
0 - 95% non-condensing
IP68
IK07
Height 139 mm (5.47 inches)
Width 44 mm (1.73 inches)
Depth 23 mm (0.9 inches)
20
Multi Tech Reader
Maximum
Idle
2
1
175 mA
115 mA
113 mA
100 mA
3
Maximum
2
164 mA
124 mA
Page 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T15 mifare reader whiteT15 multi tech reader whiteT15 piv mifare reader blackT15 multi tech reader blackT15 piv mifare reader whiteT15 piv multi tech reader black ... Show all

Table of Contents