Page 2
Although every commercially reasonable effort has been taken to ensure the quality and accuracy of the information, Gallagher Group makes no representation as to its accuracy or completeness and it should not be relied on as such. To the extent permitted by law, all express or implied, or other representations or warranties in relation to the information are expressly excluded.
Introduction The Gallagher T12 Reader is a mobile credential and smart card proximity reader. It can be installed as either an entry reader or exit reader. It can be mounted on a BS 4662 British Standard square flush box. The reader sends information to the Gallagher Controller and acts upon information sent from the Gallagher Controller.
Page 5
2.2 Power supply The Gallagher T12 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals. The operating current draw is dependant on the supply voltage at the reader. For the Mifare reader, at 13.6 Vdc the current draw is 84 mA (idle). During card read, beeper and LED activity, the current will momentarily reach 113 mA (maximum).
Ensure both you and the equipment are earthed before beginning any servicing. The Gallagher T12 Reader is designed to be mounted on a standard British electrical flush box, or any solid flat surface. However installation on metal surfaces, particularly those with a large surface area will reduce read range.
Page 8
Reader, as shown in the following diagrams. Note: Mobile credential readers must be connected as HBUS Readers. An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
The reader is idle. Peak current during card read. Gallagher T Series readers are UL humidity tested and certified to 85% and have been independently verified to 95%. Note: The current values stated above have been reported using the default configuration for a reader in Command Centre.