Installation - Gallagher T15 Mifare Reader Black Installation Note

Hide thumbs Also See for T15 Mifare Reader Black:
Table of Contents

Advertisement

4

Installation

ATTENTION: This equipment contains components that can be damaged by
electrostatic discharge. Ensure both you and the equipment are earthed before
beginning any servicing.
The Gallagher T15 Reader is designed to be mounted on any solid flat surface. However installation on
metal surfaces, particularly those with a large surface area will reduce read range. The extent to which
the range is reduced will depend upon the type of metal surface.
The recommended mounting height for the reader is 1.1 m (3.6 ft) from the floor level to the centre of
the reader device. However this may vary in some countries and you should check local regulations for
variations to this height.
1.
Use the reader base as a guide to drill all three holes. Drill the 13 mm (1/2 inch) diameter centre
hole (this is the centre hole for which the building cable will exit the mounting surface) and the
two fixing holes.
2.
Run the building cabling out through the centre hole and through the reader base.
3.
Secure the base to the mounting surface using the two fixing screws provided. It is important the
base of the reader is flush with and tight against the mounting surface. Three screw locations
have been provided. Gallagher recommend using the outer screw locations.
Note: It is strongly recommended that you use the screws provided. If an alternative screw is
used, the head must be no larger nor deeper than that of the screw provided.
Note: Ensure the centre hole allows the cable to run freely out through the mounting surface, so
that the reader facia can clip into the base.
No. 6 pan head screw
Building cable
No. 6 pan head screw
4.
Connect the reader tail extending from the facia assembly to the building cable. Connect the
wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV
Reader, as shown. T15 PIV Readers must be connected as HBUS Readers.
An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to
a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
3E4237 Gallagher T15 Reader | Edition 1 | June 2016
Copyright © Gallagher Group Limited
Base
Page 8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T15 mifare reader whiteT15 multi tech reader whiteT15 piv mifare reader blackT15 multi tech reader blackT15 piv mifare reader whiteT15 piv multi tech reader black ... Show all

Table of Contents