ATTENTION: This equipment contains components that can be damaged
by electrosta c discharge. Ensure both you and the equipment are earthed
before beginning any servicing.
The Gallagher T11 Reader
The Gallagher T11 Reader is a smart card proximity reader. It can be installed as
either an entry reader or exit reader. It can be mounted on a ver cal, rectangular
50 mm x 75 mm (2" x 3") fl ush box with moun ng holes spaced at a nominal 85 mm
(3.25").
The Mifare reader reads: Mifare DESFire EV1, Mifare Plus and Mifare Classic cards.
The Mul Tech reader reads: Mifare DESFire EV1, Mifare Plus, Mifare Classic and
125 kHz cards.
The reader sends informa on to the Gallagher Controller and acts upon informa on
sent from the Gallagher Controller. The reader itself does not make any access
decisions.
The Gallagher T11 Reader uses the "Cardax IV Reader" communica ons protocol to
communicate with the Gallagher Controller.
Note: A French transla on of this document can be downloaded from the Gallagher
Support Site: h p://support.gallagher.co
IMPORTANT: Gallagher T11 Mul Tech readers only:
Using dual technology 125/Mifare cards with Gallagher T11 Mul Tech readers
may cause both card technologies to be read, resul ng in double card badges
and unusual reader feedback. Gallagher strongly recommends against using dual
technology 125/Mifare cards with Gallagher Mul Tech readers for sites running
pre-Command Centre v7.00 so ware (due for release 2nd half, 2011). From
Command Centre v7.00, a site may specify which technology a Mul Tech reader
should read off a dual technology card.
Part Number: 3E2513 | Edi on 10
November 2012
Installa on Note
Gallagher T11 Reader
Page 1

Advertisement

loading

Summary of Contents for Gallagher T11

  • Page 1 The Gallagher T11 Reader The Gallagher T11 Reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader. It can be mounted on a ver cal, rectangular 50 mm x 75 mm (2” x 3”) fl ush box with moun ng holes spaced at a nominal 85 mm (3.25”).
  • Page 2: Before You Begin

    The performance of the reader may be aff ected by a low quality, noisy power supply. Cabling The Gallagher T11 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm ) stranded security cable. This cable allows the transmission of data (2 wires) and power (2 wires).
  • Page 3: Distance Between Proximity Readers

    200 mm (8 inches) away. Installa on The Gallagher T11 Reader is designed to be mounted on ver cally orientated electrical fl ush (gang) boxes, or any solid fl at surface. However installa on on metal surfaces, par cularly those with a large surface area will reduce read range.
  • Page 4 Gallagher T11 Reader Installa on Note If you are not moun ng to a fl ush box, secure the base to the moun ng surface using the four fi xing screws provided. Base 6-32 UNC screw Building cable 6-32 UNC screw Connect the reader tail extending from the facia assembly to the building cable.
  • Page 5 Fit screw to secure facia to base Removal of the facia assembly is a simple reversal of these steps. Connec ons A Gallagher T11 Reader can connect to one of the following devices using the “Cardax IV Reader” communica ons protocol: •...
  • Page 6 Gallagher T11 Reader Installa on Note Connec ng to the Gallagher Reader Module (for the Controller 6000) Connect the wires to the sockets as shown: Nega ve Black Gallagher Reader Module Posi ve Reserved Orange Reserved Green Reserved Brown CDXIV RX...
  • Page 7 Installa on Note Gallagher T11 Reader Connec ng to the Gallagher Controller 3000-4R or 3000-8R The ports to which the Gallagher T11 Reader can connect are set up as groups, as follows: • Two groups (numbered 1 and 2) on the Controller 3000-4R, and •...
  • Page 8 Gallagher T11 Reader Installa on Note Make the connec ons from the Gallagher T11 Reader to either the Gallagher Controller 3000-4R or 3000-8R as shown: Gallagher Controller 3000-4R or 3000-8R Group PB1 and PA1... to... PB2 and PA2 (3000-4R) PB4 and PA4 (3000-8R)
  • Page 9: Approvals And Standards

    Installa on Note Gallagher T11 Reader Technical Specifi ca ons Technical Specifi ca ons Rou ne maintenance: Not applicable for this reader. Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth. Power required: Voltage: 9 Vdc - 16 Vdc...
  • Page 10 Note: Changes or modifi ca ons not expressly approved by Gallagher Group Limited could void the user’s authority to operate this equipment. Page 10 Edi on 10 | Part Number: 3E2513...
  • Page 11: Drill Template

    Drill Template 13 mm (1/2 inch) diameter hole for cable 22.5 mm (0.89 inches) 40 mm (1.57 inches) 70 mm (2.76 inches)