5.2.2 Jog Operation 2-Fwd/Rev Jog by Multi-function Terminal

For jog operation 1, an operation command must be entered to start operation, but while using
jog operation 2, a terminal that is set for a forward or reverse jog also starts an operation. The
priorities for frequency, Acc/Dec time and terminal block input during operation in relation to
other operating modes (Dwell, 3-wire, up/down, etc.) are identical to jog operation 1. If a different
operation command is entered during a jog operation, it is ignored and the operation maintains
the jog frequency.
Group Code
Name
dr
11
Jog frequency
12
Jog operation
acceleration time
13
Operation
deceleration time
In
65-71 Px terminal
configuration

5.2.3 Jog Operation by Keypad

Group Code
Name
Dr
90
[ESC] key functions
06
Command source
* Displayed under DRV-06 on the LCD keypad.
128
LCD Display
Parameter setting Setting Range
JOG Frequency
10.00
JOG Acc Time
20.00
JOG Dec Time
30.00
Px Define(Px: P1-P7) 46 FWD JOG
47 REV JOG
LCD Display
Parameter Setting Setting Range Unit
-
1
Cmd Source* 0
0.50-Maximum
frequency
0.00-600.00
0.00-600.00
-
JOG Key -
Keypad -
Unit
Hz
sec
sec
-
-
-