44
Simon XT
Installation Manual

Timers

Table 18 provides timer option details.

Table 18. Timers

Function
Default
Latchkey time
Off
Entry delay
030 seconds
Exit delay
060 seconds
No activity tm
Off
Auto phone test
Off
Supervisory time 12:00am
Alarm cancel
006
RF time-out
12 hours
Description
Determines whether the panel reports a latchkey alarm if the system is not disarmed at
a preset time between midnight and 11:59 P.M. (on). If the latchkey feature is disabled
(off), the panel will not report a latchkey alarm.
The system clock must be set for the latchkey feature to work.
Determines how much time the user has to disarm the system after entering the armed
premises through a designated delay door, before an alarm occurs. Beeps sound during
the entire delay time to remind the user to disarm the system.
When turned on, the Entry Delay can be set from 005 to 240 seconds (030 to 240
seconds if SIA limits option is on).
Determines how much time the user has to leave the premises through a designated
delay door after arming the system. Beeps sound after arming the system to remind the
user to leave the armed premises. If a delay door is opened after the Exit Delay expires,
the Entry Delay begins. If the user arms the system with No Delay and opens a delay
door after the Exit Delay expires, an alarm occurs.
When turned on, the Exit Delay can be set from 005 to 254 seconds (045 to 254 seconds
if SIA limits option is on).
Determines whether the panel sends a No Activity report to a central station when the
programmed time period elapses (on), or if the feature is disabled (off).
No activity means control panel, remote handheld, and key-chain touchpad buttons
have not been pressed and sensors have not been tripped within a specified period of
time (except sensors in group 25).
The timeout can be set from 02 to 24 hours.
Determines whether the panel automatically performs a periodic phone test (on) or not
(off). The test interval can be from 001 to 254 days. The time of day the panel performs
the test is determined by Supervisory Time, which must be turned on for this feature to
work.
Determines when the panel reports supervisory conditions (sensor failures) and
automatic phone tests to the central station.
The panel clock must be set to the correct time for this option and the automatic phone
test to work correctly.
Sets the time frame that determines whether the panel reports an alarm cancel message
to the central station. If the system is disarmed from an alarm state within the
programmed time, the panel sends an alarm cancel message to the central station. An
alarm cancel message is not reported if the system is disarmed after the programmed
time expires.
The time can be set from 006 to 255 minutes. When set to 255, the panel always reports
alarm cancel messages. Turning off this option disables alarm cancel reporting.
Determines the time period the panel must receive at least one supervisory signal from
learned sensors before identifying a sensor failure and sounding trouble beeps. Any
sensor failure is reported immediately and again at the supervisory time (Supervisory
Time). The timeout can be set from 02-36 hours. Entries must be two digits.