GE Security Simon XT Installation Manual page 52

Hide thumbs Also See for Simon XT:
Table of Contents

Advertisement

42
Simon XT
Installation Manual
Table 16. Reporting options (continued)
Function
Default
Closing reports
Off
Force armed
Off
AC power failure
Off
Low CPU battery On
Sen alarm
Off
restore
24-hour sensor
Off
tamper
Supervisory
Off
tamper
No usage
Off
Description
Determines whether the panel sends closing reports to a central station whenever the
system is armed (on), or not (off). User number will be reported as zone number. Keyfobs
learned into zones 1 through 40 will report as the zone they are learned into.
Dealer code = 44
Installer code = 45
Master code = 46
User code 1 = 47
User code 2 = 48
User code 3 = 49
User code 4 = 50
User code 5 = 51
User code 6 = 52
User code 7 = 53
User code 8 = 54
Duress code = 55
Determines whether the panel sends a force armed report to a central station if the user
bypasses protesting sensors (indirect bypass) when arming the system (on) or not (off).
Determines whether or not the panel sends AC power failure reports to a central station
after the programmed time expires. The time can be set from 005-254 minutes.
• When the panel is without AC power for 30 seconds, the panel LEDs turn off.
• When the panel is without AC power for the programmed time, an AC power failure
is reported.
• The panel reports an AC power restoral when AC power returns to the panel.
Determines whether the panel sends a low CPU battery report to the central station
when the panel backup battery voltage drops
Determines whether the panel reports sensor alarm restorals (on) or not (off). Setting
when restorals are reported:
1.
Immediately after sensor is closed or restored after dial delay.
2.
After siren timeout expires if sensor is restored.
3.
When system is disarmed if sensor is restored.
Determines whether the system (armed or disarmed) goes into and reports an alarm
anytime a sensor tamper switch is tripped (on), or only when the system is armed and a
tamper switch of an armed sensor is tripped (off).
Determines whether the panel sends supervisory reports to a central station as a tamper
(on) or a supervisory (off).
This option is typically used only in Europe where a supervisory condition is required to
report as a tamper.
Determines whether the panel sends a No Usage report to the central station if the user
has not operated the system before the programmed time expires (on) or not (off). The
timer starts each time the system is disarmed.
This is a customer service feature that alerts the central station if a customer is not using
their security system. The service provider can then contact the customer to find out
why the system is not being used, and help correct any problems for the customer.