Connecting Hardwired Devices; Hw1 I/O, Hw2 In, And Hw1&2 Dc Out Terminals; Interior Sirens - GE Security Simon XT Installation Manual

Hide thumbs Also See for Simon XT:
Table of Contents

Advertisement

20
Simon XT
Installation Manual

Connecting hardwired devices

The panel has seven screw terminals and two telephone connections (Figure 5). The screw terminals connect
AC power, sirens, and/or hardwired detectors.
Program sensors and devices before you install them. Follow the instructions in Chapter 4
Programming
to
add the sensors to panel memory.
Figure 5. Simon XT terminal connections
HW2 in
9 VAC in
HW1&2 DC out
Battery +
RJ45 connector (LINE)
HW1 I/O
Battery –
RJ11 connector (PHONE)
Battery compartment
Tamper switch
HW1 I/O, HW2 in, and HW1&2 DC out terminals
The HW1 I/O terminal is dual purpose and can be used for either siren or hardwired contact connections. The
HW2 in terminal is an input only.

Interior sirens

From the factory, the HW1 I/O input is set up for interior siren operation (status and alarm sounds). HW1&2
DC out provides the positive (+) voltage.
Note:
The total current available from the HW1&2 DC out terminal is 250 mA at up to 122°F (50°C).
With Hardwired Siren Supervision turned on, sirens connected to HW1 I/O are supervised and require a
4.7 kohm resistor in the circuit. If this terminal is not used, turn Hardwired Siren Supervision off.