Installation Of Drain Saddle - AQUALUX AQLXC-5RO Operating Manual

5-stage reverse osmosis system
Table of Contents

Advertisement

TO INSTALL THE SADDLE VALVE ON STEEL OR BRASS PIPE
1.
Shut off water supply and drain the line.
2.
Drill a 3/16" hole in pipe. Use a hand drill to avoid shock hazard.
3.
Turn handle to expose lance beyond the rubber gasket no more than 3/16"
4.
Place body of valve over hole so that lance fits into the hole.
5.
Tighten bottom clamp evenly-Brackets should be parallel.
6.
Turn handle clockwise to close valve.
7.
Open the water supply and allow water to run from sink for a few minutes to clean any debris in the line
caused by installation.
8.
Turn handle counter clockwise to open valve.
1.
The drain saddle should be installed above the trap on the vertical or horizontal tailpipe.
2.
Drill a ¼" hole into the drain pipe observing the above positioning.
NOTE: If positioning on the horizontal pipe (preferred location) the hole for the drain saddle should be drilled
at a slight incline to avoid noise.
To avoid noise on the vertical pipe, position the drain saddle low above the trap.
3.
Mount drain saddle, aligning holes.
4.
Carefully tighten the bracket screws evenly keeping the brackets parallel.

INSTALLATION OF DRAIN SADDLE

drainSaddle
a t either
loc a tion
Never
mount
he re
Mo unt