Troubleshooting Guide - AQUALUX AQLXC-5RO Operating Manual

5-stage reverse osmosis system
Table of Contents

Advertisement

TROUBLE SHOOTING GUIDE
SYMPTOM
PROBABLE CAUSE
SOLUTION
No water
Water supply is turned off
Turn water on
Not enough water
Low water pressure
Unit will not operate at less than
35 psi household line pressure
Water supply blocked
Clear restriction, rotate valve
handle on tap water feed assembly
Storage tank depleted
Consider adding additional tank
to your system if this occurs frequently
Clogged pre-filter restricting
Replace pre-filter
water flow
No drain water
Clogged brine restrictor
Replace brine restrictor
Leaking drain assembly or leak
Misalignment of hole in drain saddle
Realign drain saddle
Leaking from air gap opening in
Hole or drain tube is blocked
Remove debris
faucet
Excessive noise coming from
Excessive slack in drain tubing
Cut off excessive tubing
faucet
Water has offensive taste or odor
Carbon post filter depleted
Drain storage tank and replace carbon
post filter cartridge
Membrane depleted or fouled
If TDS rejection is below 70% replace
membrane
Not enough product water pressure
Low air tank charge
Empty water from storage tank and
adjust air pressure in tank to 5-7 psi.