Table of Contents

Advertisement

3.
Remove the server from the rack (Removing the server from the rack on page 39).
4.
Remove the access panel (Removing the access panel on page 40).
5.
Do one of the following:
Remove the secondary PCIe riser cage (Removing the PCIe riser cages on page 44).
Remove the tertiary PCIe riser cage (Removing the PCIe riser cages on page 44).
6.
Install the microSD card.
7.
Do one of the following:
Install the secondary PCIe riser cage (Installing the secondary PCIe riser cage on page 68).
Install the tertiary PCIe riser cage (Installing a tertiary PCIe cage on page 70).
8.
Install the access panel (Installing the access panel on page 41).
9.
Install the server into the rack (Installing the server into the rack on page 34).
10. Connect each power cord to the server.
11. Connect each power cord to the power source.
12. Power up the server (Powering up the server on page 38).

Installing an intrusion detection switch

Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit
Procedure
1.
Power down the server (Power down the server on page 38).
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack (Extend the server from the rack on page 38).
Remove the server from the rack (Removing the server from the rack on page 39).
4.
Remove the access panel (Removing the access panel on page 40).
5.
Install the intrusion detection switch.
Installing an intrusion detection switch
107