Extend the server from the rack (Extend the server from the rack on page 38).
Remove the server from the rack (Removing the server from the rack on page 39).
4.
Remove the access panel (Removing the access panel on page 40).
5.
If installed, do the following:
a. Remove the air baffle (Removing the air baffle on page 42).
b. Remove the processor mezzanine tray (Removing the processor mezzanine tray on page 47).
c. Remove the 2P pass-through performance board (Removing the 2P pass-through performance
board on page 48).
6.
Remove the fan cage (Removing the fan cage on page 46).
7.
Remove the screws, and then remove the drive bay blank.
8.
Install the drive cage.
9.
Route and connect the cables depending on the server configuration. For more information, see
"Cabling on page 109."
To cable the drive cage to the HPE 12G SAS Expander, see "Installing the HPE 12G SAS Expander
Card on page 96."
10. Install the fan cage.
11. If removed, do the following: