Configuring A Recording Cycle - Satimo EME Guard User Manual

Personal exposure meter
Table of Contents

Advertisement

Figure 12 : Battery level too low – warning message

3.3.1 Configuring a recording cycle

The administrator can activate or de-activate the recording cycle.
Recording period: time in seconds between two consecutive recordings. This time
must be between 1 second and 255 seconds. The recording duration can then be
established.
Recording duration: total time (in minutes) of the measurement recording cycle. The
number of measurements to be recorded during the cycle corresponds to:
where
CycleDurat
ion
Figure 13 : Recording cycle off
Figure 14 : Recording cycle on
NumberOfMe
asures
is expressed in minutes.
×
CycleDurat
ion
=
Period
20 / 37
60

Advertisement

Table of Contents
loading

Table of Contents