Stopping The Device; Recharging The Battery; Precautions For Use; Nterpretation Perations Ights - Satimo EME Guard User Manual

Personal exposure meter
Table of Contents

Advertisement

2.4
S
TOPPING THE
The dosimeter can be switched off at any moment by pressing the ON / OFF button. The
button must be depressed for one or two seconds until the ON light switches off. This is so
that if the button is pressed accidentally the device will not be switched off.
3 audio beeps are emitted, indicating that the device is switching off.
If switched off in mid measurement cycle, the cycle will pick up where it left off when the
dosimeter is switched back on. This downtime will not be recorded in the total time of the
measurement recording cycle.
2.5
I
NTERPRETATION
ON
Off
Flashing
off
25%
50%
Off
Off
On
Off
Off
On
Off
Off
Off
Off
2.6
R
ECHARGING
The battery must only be recharged using the battery charger provided.
The following advice and instructions will help you to use the charger more effectively and
to recharge the battery correctly.

2.6.1 Precautions for Use.

The battery charger has been designed for interior use only and must not come into
contact with water or dust.
To avoid overheating, the charger must not be covered when in use.
The mains electric socket must be easily accessible. If an operating error occurs, the
charger must be unplugged immediately.
The charger is designed to be used exclusively with lithium-ion batteries.
D
EVICE
O
O
F
PERATIONS
Light Status – operation indicators
Lights
BATT.
off
off
flashing
Light Status – visual alarm (field measurements)
Lights
75%
100%
Off
Off
Off
Off
Off
Off
On
Off
Off
On
T
B
HE
ATTERY
L
IGHTS
indicating
The dosimeter is switched off (all lights are off).
The dosimeter is taking measurements.
Battery power is too low to take accurate readings,
measurements have stopped.
indicating
The field measured is strictly inferior to 25% of the
chosen reference threshold.
The field measured is greater than or equal to 25%
of the chosen reference threshold and less than 50%
of the chosen reference threshold.
The field measured is greater than or equal to 50%
of the chosen reference threshold and less than 75%
of the chosen reference threshold.
The field measured is greater than or equal to 75%
of the chosen reference threshold and less than
100% of the chosen reference threshold.
The field measured is greater than or equal to 100%
of the chosen reference threshold.
14 / 37

Advertisement

Table of Contents
loading

Table of Contents