Nvme Ssd Components - HP ProLiant DL360 Gen10 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL360 Gen10:
Table of Contents

Advertisement

Item
LED
1
Locate
2
Activity ring
3
Do not remove
4
Drive status

NVMe SSD components

The NVMe SSD is a PCIe bus device. A device attached to a PCIe bus cannot be removed without allowing
the device and bus to complete and cease the signal/traffic flow.
CAUTION:
Do not remove an NVMe SSD from the drive bay while the Do Not Remove button LED is flashing. The
Do Not Remove button LED flashes to indicate the device is still in use. Removal of the NVMe SSD
before the device has completed and ceased signal/traffic flow can cause loss of data.
Status
Definition
Solid blue
The drive is being identified by a host
application.
Flashing blue
The drive carrier firmware is being updated or
requires an update.
Rotating green
Drive activity.
Off
No drive activity.
Solid white
Do not remove the drive. Removing the drive
causes one or more of the logical drives to fail.
Off
Removing the drive does not cause a logical
drive to fail.
Solid green
The drive is a member of one or more logical
drives.
Flashing green
The drive is rebuilding or performing a RAID
migration, strip size migration, capacity
expansion, or logical drive extension, or is
erasing.
Flashing amber/
The drive is a member of one or more logical
green
drives and predicts the drive will fail.
Flashing amber
The drive is not configured and predicts the
drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID
controller.
NVMe SSD components
93

Advertisement

Table of Contents
loading