Installation Instructions (Incl. Electrical Installation) - Belling 487 Installation And User Instructions Manual

Multifunction double oven
Table of Contents

Advertisement

Important
Before Cooking
Electrical
Requirements
Electrical
Connections
6
Installation Instructions
This equipment is designed specifically for domestic purposes
and Belling Appliances Limited cannot accept responsibility if used in any
other type of installation.
This appliance must not be installed over any appliance that
generates heat.
Note: When the cooker is first used, an odour may be emitted - this
will cease after a short period of use.
To help remove the 'new' smell, heat up the empty ovens to maximum
temperature for a minimum of two to three hours keeping the oven doors
closed.
Ensure the room is well ventilated (e.g. open a window or use an extractor
fan) and that persons who may be sensitive to the odour avoid any fumes.
It is suggested that any pets be removed from the room until the smell has
ceased. This odour is due to any temporary finish on oven linings and
elements and also any moisture absorbed by the insulation.
For your own safety, we recommend that your appliance is installed
by a qualified electrician. The cooker should be installed in
accordance with the latest Edition of the IEE Regulations.
WARNING:– THIS APPLIANCE MUST BE EARTHED.
THE INSTALLER MUST check that the voltage shown at the rating plate
corresponds with the house electricity supply.
The oven must be supplied via a 32 amp double pole isolating switch,
having a contact separation of at least 3mm in all poles placed in a readily
accessible position adjacent to the unit.
The maximum loading for your oven is 6.4kW.
If the oven is to be wired into a connector unit this may be positioned
behind the oven provided the following requirements are met:
i)
The connector unit must not project from the wall more than
25mm.
ii) The top of the connector must not be more than 350mm above
the base.
Remove the terminal cover at the rear base of the oven. Pass the cable
through the cable clamp and connect to the appropriate
terminals provided. Allow sufficient cable so that the oven can be set
down on the floor whilst still connected up. Tighten the screws on the
cable clamp and replace the terminal cover. Make mains connections.
This appliance conforms to B.S. EN 55014 regarding suppression of Radio
and Television reception interference.
Where a double oven is used a 32 amp double pole control switch should
be used to feed the unit using a suitable rated cable. We recommend that
a minimum of 4mm
B.S. 6004. Where a hob is fitted adjacent to an oven then a 45 amp Double
Pole control switch should be used to feed both units via separate suitably
rated cables. We recommend that a minimum of 4mm
and earth cable conforming to B.S. 6004.
2
PVC insulated twin and earth cable conforming to
2
PVC insulated twin